Äîêóìåíò âçÿò èç êýøà ïîèñêîâîé ìàøèíû. Àäðåñ îðèãèíàëüíîãî äîêóìåíòà : http://rtm-cs.sinp.msu.ru/docs/borexino/borexinobe7.pdf
Äàòà èçìåíåíèÿ: Thu Jan 24 13:53:31 2008
Äàòà èíäåêñèðîâàíèÿ: Mon Oct 1 20:55:37 2012
Êîäèðîâêà:
First real time detection of 7Be solar neutrinos by Borexino
Borexino Collaboration C. Arpesella a,1 , G. Bellini b , J. Benziger c , S. Bonetti b , B. Caccianiga b , F. Calaprice d , F. Dalnoki-Veress d , D. D'Angelo b , H. de Kerret f , A. Derbin g , M. Deutsch h,1 , A. Etenko e , K. Fomenko i , R. Ford d,2 , D. Franco b , B. Freudiger o,1 , C. Galbiati d , S. Gazzana a , M. Giammarchi b , M. Goeger-Neff j , A. Goretti d , C. Grieb k , S. Hardy k , G. Heusser o , Aldo Ianni a , Andrea Ianni d , M. Joyce k , G. Korga a , D. Kryn f , M. Laubenstein a , M. Leung d , E. Litvinovich e , P. Lombardi b , L. Ludhova b , I. Machulin e , G. Manuzio , A. Martemianov e,1 , F. Masetti m , K. McCarty d , E. Meroni b , L. Miramonti b , M. Misiaszek n , D. Montanari a , M. E. Monzani a , V. Muratova g , L. Niedermeier j , L. Oberauer j , M. Obolensky f , F. Ortica m , M. Pallavicini , L. Papp a , L. Perasso b , A. Pocar d,3 , R. S. Raghavan k , G. Ranucci b , A. Razeto a , A. Sabelnikov e , C. Salvo a , S. Sch¨ onert o , o i e d,4 H. Simgen , O. Smirnov , M. Skorokhvatov , A. Sonnenschein , A. Sotnikov i , S. Sukhotin e , Y. Suvorov b,e , V. Tarasenkov e , R. Tartaglia a , G. Testera , D. Vignaud f , S. Vitale ,1 , R. B. Vogelaar k , F. von Feilitzsch j , M. Wo jcik n , O. Zaimidoroga i , S. Zavatarelli , G. Zuzel o
a I.N.F.N. Laboratori Nazionali del Gran Sasso ­ Assergi ­ Italy Dipartimento di Fisica del l'Universit` degli Studi e INFN ­ Milano ­ Italy a c Princeton University, Chemical Engineering Department ­ Princeton, NJ ­ USA d Princeton University, Physics Department ­ Princeton, NJ ­ USA e RRC Kurchatov Institute ­ Moscow ­ Russia f Laboratoire AstroParticule et Cosmologie APC ­ Paris ­ France g St. Petersburg Nuclear Physics Institute ­ Gatchina ­ Russia Massachussetts Institute of Technology, Department of Physics ­ Cambridge, MA ­ USA i Joint Institute for Nuclear Research ­ Dubna ­ Russia j Technische Universit¨ Muenchen ­ Garching ­ Germany at k Virginia Tech, Physics Department ­ Blacksburg, VA ­ USA Dipartimento di Fisica del l'Universit` e INFN ­ Genova ­ Italy a m Dipartimento di Chimica del l'Universit` e INFN ­ Perugia ­ Italy a n Marian Smoluchowski Institute of Physics, Jagiel lonian University ­ Krakow ­ Poland o Max-Planck-Institut fur Kernphysik ­ Heidelberg ­ Germany ¨ b

h

Abstract This paper reports a direct measurement of the 7 Be solar neutrino signal rate performed with the Borexino low background liquid scintillator detector. This is the first real-time spectral measurement of sub-MeV solar neutrinos. The result for 0.862 MeV 7 Be neutrinos is 47 ± 7stat ± 12sys counts/(day · 100 ton), consistent with predictions of Standard Solar Models and neutrino oscillations with LMA-MSW parameters.
Key words: Solar Neutrinos; Neutrino Oscillations; Low Background Detectors; Liquid Scintillators. Preprint submitted to Elsevier 5 September 2007


1. Intro duction
Counts/(10 keV â day â 100 tons)
10

We report a real-time spectroscopic observation of the mono-energetic (0.862 MeV) neutrinos ( ) from the radioactive decay of 7 Be in the Sun. These results from Borexino at the Laboratori Nazionali del Gran Sasso constitute a scientific and technological breakthrough in the quest for the real time detection of low energy (below 2 MeV) solar that comprise >99% of the flux. Current spectroscopic data on solar are confined to energies greater than 5 MeV (0.01% of the total flux). Solar neutrinos provide a unique probe for studying both the nuclear fusion reactions that power the Sun and the fundamental properties of neutrinos. The sun shines by the energy produced in a thermonuclear reaction chain built up on the fusion of four protons to produce one 4 He nucleus. The chain has three ma jor links: ppI ­ the fundamental protonproton fusion leading to the production of 3 He; ppII ­ the production of 7 Be via the reaction 3 He+4 He; ppIII ­ the production of 8 B via 7 Be+p, each step terminating with the production and accumulation of 4 He. Each of these links produces electron neutrinos (e ). The 7 Be from the ppII link decays by electron capture with a 90% branch yielding monoenergetic 0.862 MeV neutrinos. The 7 Be e contribute a substantial ( 10%) fraction of the solar e flux, whereas only 10-4 of the total e flux arises from ppIII. The 8 B neutrinos from ppIII have been intensively studied in the last decade (1; 2). The prediction of the 7 Be flux depends both on the solar model and on the cross section of the 3 He(, )7 Be reaction. The latter was recently measured with improved accuracy (3); therefore a measurement of the 7 Be flux is an important and timely test of the standard solar model. Precision measurements in Borexino are equally important for the new neutrino physics with nonzero masses, flavor mixing, and neutrino oscillations. Current neutrino data are consistent with the socalled Large Mixing Angle (LMA) solution of the Mikheyev-Smirnov-Wolfenstein (MSW) picture of flavor conversion (4; 5). The LMA solution predicts a transition from matter enhanced oscillations at 8 B
1 2

All solar neutrinos
7

Be neutrinos

1

10

-1

10

-2

10

-3

0.2

0.4

0.6

0.8 1 1.2 1.4 Energy [MeV]

1.6

1.8

2

Fig. 1. Neutrino spectra expected in Borexino (accounting for the detector's energy resolution). The solid black line represents the neutrino signal rate in Borexino according to the most recent predictions of the Standard Solar Model (11) including neutrino oscillations with the LMA-MSW parameters. The solid red line illustrates the contribution due to 7 Be neutrinos. pp neutrinos contribute to the sp ectrum b elow 0.3 MeV and the edge at 1.2 MeV is due to pep neutrinos.

energies to vacuum oscillations at low energies in the neighborhood of 7 Be neutrinos. The e survival probability increases from 0.33 at high energies up to 0.6 at low energies near the 7 Be e line. A measurement of the 7 Be neutrino rate will test the predicted increase in the e survival probability. New physics such as non-standard interactions introduce deviations from these expectations (6). Solar neutrinos have been detected in the last 40 years by two methods, the earliest being radiochemical separation after neutrino activation which yields only the integrated e flux above a threshold. Individual components of the neutrino spectrum cannot be determined by such measurements. Low energy neutrinos have been observed so far only by such methods (7; 8; 9; 10). Direct spectroscopy using kilo ton scale water Cerenkov detectors has been limited to the high energy neutrino flux above 5 MeV, owing to the low signal light yield of the Cerenkov process and to the natural radioactivity background (1; 2). 2. Exp erimental apparatus and signature from solar neutrinos

deceased now at SNOWLAB, Sudbury, Canada 3 now at Department of Physics, Stanford University, Stanford, CA, USA 4 now at Fermi National Accelerator Lab oratory, Batavia, IL, USA

Borexino employs a liquid scintillator that produces sufficient light to observe low energy neutrino events via elastic scattering by electrons. The reaction is sensitive to all neutrino flavors by the neutral current interaction, but the cross section for e is 2


Borexino Detector
External water tank Water Ropes Internal PMTs Buffer Steel plates for extra shielding Scintillator Muon PMTs Stainless Steel Sphere Nylon Outer Vessel Nylon Inner Vessel Fiducial volume

Fig. 2. Schematic drawing of the Borexino detector.

larger due to the combination of charged and neutral currents. The recoil electron profile for a monoenergetic neutrino is similar to that of Compton scattering of a single -ray. Thus, the recoil electron profile is basically a rectangular shape with a sharp cut-off edge at 665 keV in the case of 7 Be neutrinos (see Fig. 1). The background from the 156 keV decay of 14 C, intrinsic to the scintillator, limits neutrino observation to energies above 200 keV. Organic liquid scintillation technology is a viable method for massive detectors suitable for spectroscopy at such low energies, since its signal efficiency is 50 times that of the commonly used Cerenkov technology. However, no directionality is possible. Moreover, it is not possible to distinguish neutrino scattered electrons from electrons due to natural radioactivity. Thus the key requirement in the technology of Borexino is extremely low radioactive contamination. The scintillator is pseudocumene (PC, 1,2,4trimethylbenzene), a well known aromatic scintillation solvent doped with PPO (2,5-diphenyloxazole, a fluorescent dye) at a concentration of 1.5 g/l. The excitation energy of PC molecules produced by ionizing radiation is transferred non-radiatively to the PPO which then radiates with a decay time of 1.3 ns resulting in a scintillation pulse width of 3.5 ns. The scintillation signal is emitted in the optical band centered near 400 nm. At this wavelength the optical attenuation length in the scintillator is 7 m. The PC was produced by Polimeri Europa in Sardinia, Italy. Precautions, including specially constructed loading and unloading stations, were taken 3

to minimize the optical and radioactive contamination during the transportation to Gran Sasso. In particular, the PC was taken directly from the production plant and quickly shipped in a specially constructed nitrogen pressurized vessel. Techniques for purification of the scintillator employed in this work are based mainly on methods developed and tested in earlier studies with the Counting Test Facility (CTF), a 4-ton prototype of Borexino. CTF demonstrated for the first time the feasibility of achieving the low backgrounds needed to detect solar neutrinos in a large scale scintillator (12; 13; 14). For Borexino a larger purification plant was developed similar to the CTF system, but with several improved features including the use of high vacuum and precision cleaning techniques. To achieve ultra low operating backgrounds in the detector (from internal and external sources) the design of Borexino is based on the principle of graded shielding with the scintillator at the center of a set of concentric shells of increasing radiopurity (see Fig. 2). The 300-ton scintillator is contained in a thin (125 µm) nylon Inner Vessel (IV) with a radius of 4.25 m (16). Within the IV a fiducial mass is defined by software selection of the events based on their reconstructed position using timing data from the PMTs. A second nylon outer vessel (OV) with radius 5.50 m contains a passive shield composed of pseudocumene and 5.0 g/l DMP (dimethylphthalate), a material that quenches the residual scintillation of PC so that spectroscopic signals arise dominantly from the interior of the IV. The OV acts as a barrier against radon and other background contaminations originating from outside. The third vessel is a stainless steel sphere (SSS) with radius 6.85 m that encloses the PC-DMP buffer fluid which fills the space between the OV and the SSS. The SSS also serves as a support structure for the PMTs. Finally, the entire detector is contained in a tank (radius 9 m, height 16.9 m) of ultra-pure water. The total liquid passive shielding of the central volume from external radiation (such as the rock) is thus 5.5 m of water equivalent (m.w.e). The scintillator material in the IV is less dense than the buffer fluids by about 0.1%; this results in a slight upward buoyancy force on the IV. Thin low-background ropes made of ultra-high density polyethylene hold the nylon vessels in place. The scintillation light is viewed by 2212 8" PMTs (ETL 9351) uniformly distributed on the inner surface of the SSS (17; 18). All but 384 photomultipliers are equipped with aluminum light concentra-


tors designed to increase the collection efficiency of the light from the scintillator and to reduce the number of photons not coming from the scintillator volume (19). Residual background scintillation and Cerenkov light that escape quenching in the buffer are thus reduced. The PMTs without concentrators can be used to study this background as well as help identify muons that cross the buffer and not the inner vessel. All internal components of the detector were selected for low radioactivity (14). The predicted background in the fiducial volume and in the range 250­800 keV is less than 0.5 counts/(day · 100 ton) (13; 14). Besides being a powerful shield against external backgrounds ( 's and neutrons from the rock), the Water Tank (WT) is equipped with 208 PMTs and acts as a Cerenkov muon detector (see Fig. 2). The muon flux, although reduced by a factor 106 by the 3800 m.w.e. depth of the Gran Sasso Laboratory, is still significant (1.1 muon m-2 h-1 ) and an additional reduction (by about 104 ) is necessary. See Ref. (20) for a detailed description of the detector, the electronics, the trigger, and the calibration system. Since the inner nylon vessel is in direct contact with the scintillator, extreme precautions were taken in the fabrication and assembly of the nylon vessels. The nylon was selected for low radioactivity and extruded into film under carefully controlled conditions, then sealed in special bags to prevent dust and exposure to radon from the air. The nylon vessels were built in a hermetically sealed Class-100 clean room. A novel radon filter provided low-radon make-up air for the clean room to minimize surface deposit of the long-lived 210 Pb radon daughter (15). The two vessels were nested in the clean room, then shipped to the Gran Sasso Laboratory and installed in the SSS maintained as a Class-10,000 clean room. For details on the nylon vessel fabrication and installation see Ref. (16). After the nylon vessels were installed and inflated, they were purged to remove radioactive 39 Ar and 85 Kr. Purging with high purity nitrogen was carried out in stages over a period of several weeks to permit Ar and Kr trapped in stagnation regions to diffuse into the main volume and be removed. After thorough purging, the SSS and nylon vessels were filled with high purity water ( 10-14 g/g of U/Th equivalent, 1 mBq/m3 for 222 Rn and <0.8 mBq/m3 from 226 Ra). The water dissolved residual nylon monomers that caused haze and also removed metal 4

ion impurities (such as 210 Pb) from the surfaces of the vessels. Underground purification of the scintillator by distillation, water extraction, nitrogen stripping and ultra-fine filtration were key for the Borexino detector to remove contaminants from dust (U, Th, K), from the air (39 Ar, 85 Kr) and from cosmogenically produced isotopes (7 Be). Extreme air tightness was maintained to prevent reintroduction of airborne impurities into the scintillator. The scintillator solvent (PC) was distilled in-line during the detector filling at 80 mbar and at a temperature of 90­95 C in a six-plate column with a high reflux ratio at a flow rate of 800 l/hr. Distilled PC was stripped in a 15 cm-diameter, 8 m-high packed column with specially prepared ultra-low Ar/Kr nitrogen (0.005 ppm Ar and 0.06 ppt Kr, see Ref. (21)) at a reduced pressure of 250 mbar and elevated temperature of 35 C. In addition to removing radioactive contaminants the distillation of the PC was instrumental for obtaining high optical clarity. A concentrated master solution of the fluorescent component PPO in PC was prepared and purified in batch. The master solution was filtered through 0.05 µm filters, water extracted, vacuum distilled at 30 mbar and 200 C in a falling film evaporator, and lastly nitrogen stripped. The master solution was stored and metered to mix in-line with the PC solvent during the filling of the Borexino detector. The filling of the Borexino detector was done under strict control of the flow rates to each of the three volumes of the detector, inner vessel, inner buffer and outer buffer. The differential pressures, the liquid levels, and the strains in the supporting ropes were continuously monitored to sequence the flow to each volume to maintain uniform levels and differential pressures <0.5 mbar. The shapes of the nylon vessels were maintained during the filling without introducing stresses that could cause creep and shape deformation. The shapes of the vessels were also continually monitored with a specially developed internal array of cameras (27). The fluids were frequently sampled to test for optical quality, PPO and DMP concentrations. The scintillator quality was verified to satisfy stringent figures of merit. The purification system and the filling modules were pre-cleaned following a precision cleaning procedure that employed high purity cleaning agents and deionized water. The critical components of the system met the cleanliness level 30 by the standard MIL-STD-1246C for particulate specification for fluid contamination. Once cleaned, all the equip-


ment was sealed to avoid air contamination. To minimize air contamination in critical areas, the system was required to meet a stringent leak specification of <10-8 bar cm3 s-1 . Double seals with nitrogen blanketing between the seals were employed in several critical sections of the plants. For more details concerning the purifications plants and operations see Ref. (22). 3. Data acquisition and event reconstruction Monochromatic 862 keV neutrinos from 7 Be offer two signatures in Borexino. The first is a recoil electron profile with a clear Compton edge at 665 keV that is the main spectral feature used in this work to separate the neutrino signal from the residual radioactive background. The second possible signature, namely the ±3.5% annual variation of the flux due to the Earth orbit eccentricity, cannot be considered yet because of the short running time so far compared to the Earths orbital period. The scattered electrons are detected by means of the scintillation light produced in the liquid scintillator. The effective light yield was measured using the data by means of a spectral fit to the 14 C background, which dominates the count rate below 160 keV. The fit yields 500 photoelectrons/MeV, after deconvolving the light quenching effect for low energy electrons. This results is consistent with the known intrinsic light yield of the scintillator (11,000 photons MeV), the geometrical coverage (30%), the PMT quantum and collection efficiency and the scintillator light propagation mechanisms that have been extensively studied in CTF and with small scale laboratory setups (23; 24). Light absorption from PPO and reemission with 80% probability and Rayleigh scattering from PC are the two dominant mechanisms influencing the light collection in Borexino and making the effective light yield very uniform for events produced within the fiducial volume. The position of the 210 Po charge peak and the 14 C spectrum have been studied for events reconstructed within shells centered at various radii, obtaining the result that the effective light yield only decreases by 2% going from events reconstructed in the detector center to events reconstructed at a radius of 3.5 m. The scintillation light is collected by the PMTs, and for each detected photon the arrival time and the charge are measured by means of a suitable analog and digital electronics chain. As described in 5

greater detail in Ref. (20), the Borexino main trigger fires when at least Kthr PMTs each detect at least one photoelectron within a time window of 60 ns. The typical value was Kthr = 30 in the data runs used in this paper, corresponding approximately to an energy threshold of 60 keV. When a trigger occurs, the time and the charge of each PMT that has detected at least one photoelectron in a time gate of 7.2 µs is recorded. The time is measured by a Time to Digital Converter (TDC) with a resolution of about 0.5 ns, while the charge (after integration and pulse shaping) is measured by means of an 8 bit Analog to Digital Converter (ADC). This time resolution is smaller than the intrinsic time jitter of the PMTs which is 1.1 ns. The trigger was designed to detect fast delayed coincidence with high efficiency. Events that are closer than 7 µs (such as 212 Bi-212 Po and 85 K r delayed coincidences) are detected in a single trigger gate. Delayed coincidences separated by more than 7 µs are detected in two separate events with a dead time of 5 µs. The detection efficiency of 214 Bi-214 Po concidences exceeds 95%. The readout sequence can also be activated by the outer detector by means of a suitable triggering system which fires when at least six PMTs detect light in a time window of 150 ns. Regardless of the trigger type, both inner and outer detectors are always read. For detector monitoring and calibration purposes, every two seconds, all inner detector PMTs are synchronously illuminated by a 394 nm laser pulse through a set of optical fibers that reach all PMTs. These laser triggers are used for precise time alignment and charge equalization and calibration of all channels. A similar system based on a set of LEDs is used for the outer detector. The typical triggering rate during the runs analyzed in this paper was 15 Hz, including all trigger types. This rate is largely dominated by very low energy 14 C events. Two independent offline analysis codes were employed to reconstruct the time, charge and position of each recorded event. As a first step in the offline analysis, the codes identify in the recorded gate the clusters, that is, groups of time-correlated hits that belong to a unique physical event. Generally, only one cluster is found in each event gate, but in the case of fast coincidences like 212 Bi-212 Po and 85 Kr-85m Rb, or in the case of accidental pile up, more than one scintillation event may be recorded within the same trigger gate, yielding more than one reconstructed cluster from one event. Piled-up


Counts/(5 photoelectrons â day â 100 tons)

105 104 103 102 10 1 1010
1

All data After fiducial cut and removal of Rn daughters A f t er s t a t i s t i c a l s u b t r a c t i o n o f s

50 0
2 14

Bi /

2 14

Po

40 0

Counts

30 0

20 0

10 0

-2

0 -0 .1 -0 .08 -0 .06 -0 .04 -0 .02

0

0 .0 2 0 .0 4 0 .0 6 0 .0 8

0 .1

10-3 0

200

Gatti / Discrimination Parameter

400 600 Charge [photoelectrons]

800

1000

Fig. 3. Distribution of the Gatti / discrimination variable for 214 Bi-214 Po events tagged by means of their fast 236 µs delayed coincidence. The left solid blue curve is the distribution of the events, while the right solid red curve represents the events.

events resulting from the superposition of two different scintillation events within a few hundred ns are identified and rejected in the course of the analysis. The efficiency of the clustering algorithm was checked by means of random triggers and found to be nearly 100% for events with more than 20 hits. The position is determined using a photon time of flight method. A probability density function (pdf ) was developed using Monte Carlo simulations and checked on the CTF and in Borexino. The resolution in the event position reconstruction is 13±2 cm in x and y coordinates, and 14±2 cm in vertical z axis at the relatively high 214 Bi-214 Po energies. The agreement of the above numbers demonstrates the near spherical symmetry of the detector. The spatial res olution is expected to scale as N where N is the number of detected photoelectrons (25). This was confirmed by determining the 14 C spatial resolution to be 41±6 cm (1 ) at 140 keV, as expected. By measuring the position of each event we define a fiducial volume such that the residual external background mainly due to the PMT assembly, and in small part to the radioactivity of the nylon vessel, can be efficiently rejected. The time profile of the hits of each cluster is also used to determine the event type. Particularly, muons crossing the buffer (if not tagged by the outer detector), particles and -like events can be identified by means of the mean time of the hits in the cluster, of the ratio between the number of hits in the tail and the total number of hits (tail-to-total ratio), and of several / discriminating procedures like the Gatti opti6

Fig. 4. The raw photoelectron charge spectrum after the basic selection cuts (i­ii) (black), the spectrum after the subtraction of Rn daughters and muon-correlated activity, and after the application of the fiducial cut (iii­v) (blue), and with full / statistical subtraction of the 210 Po peak (red). All curves scaled to the exposure of 100 day · ton. Cuts are described in the text.

mal filter (26). An example of the / discrimination obtained by the Borexino detector is shown in Fig. 3 for 214 Bi-214 Po events.

4. Event selection and sp ectral fits The data used in this paper were collected for 47.4 live days between May and July 2007. Events are selected by means of the following cuts: (i) The event must have a unique reconstructed cluster, in order to reject pile-up events and fast coincident events. The efficiency of this cut is nearly 100% because the very low triggering rate results in a negligible pile-up. (ii) Events with a muon flag, i.e. those with some Cerenkov light in the water tank detector, are rejected. (iii) After each muon that crosses the scintillator, all events (afterpulses and spurious events) within a time window of 2 ms are rejected. The measured muon rate in Borexino (muons that cross the scintillator and buffer volume) is 0.055±0.002 s-1 . The dead time introduced by this cut is negligible. (iv) The Rn daughters occurring before the 214 Bi-214 Po delayed coincidences are eliminated by vetoing events up to three hours before a coincidence within a radial cut of 85 cm. The loss of fiducial exposure due to


Counts/(10keV â day â 100 tons)

103

7

102

Fit: 2/NDF = 22.2/21 Be: 49±7±12 cpd/100 tons 210 Bi+CNO: 19±3±5 cpd/100 tons 85 Kr: 16±9±5 cpd/100 tons

Counts/(10 keV â day â 100 tons)

2.5

2.0

Fit: 2/NDF = 41.9/47 7 Be: 47±7±12 cpd/100 tons 210 Bi+CNO: 15±4±5 cpd/100 tons 85 Kr: 22±7±5 cpd/100 tons 210 Po: 0.9±1.2 cpd/100 tons

1.5

10
Fit Region

1.0

1

0.5

10-

1

0

300

400

500

600

700

800

300

400

500

600

700

800

Energy [keV]

Energy [keV]

Fig. 5. The fit to the 7 Be region without using / statistical subtraction. The fit is done between 560 and 800 keV.

Fig. 6. Sp ectral fit in the energy region from 270 keV up to 800 keV after / statistical subtraction of the 210 Po p eak.

this vetoing process is 0.7%. (v) The events must be reconstructed within a spherical fiducial volume corresponding nominally to 100 ton in order to reject external background. Another volumetric cut (z <1.8 m) was applied in order to remove a small background from 222 Rn daughters in the north pole of the inner vessel, resulting in a nominal fiducial mass of 87.9 t. The fiducial exposure in 47.4 days is 4136 day · ton. Figure 4 shows the effect of the selection cuts starting from the total raw count spectrum. The solid black curve is the initial spectrum with only cuts (i-ii) applied. At low energies, below 100 pe, the spectrum is dominated by 14 C decays intrinsic to the scintillator. The peak at 200 pe is due to particles from 210 Po decay, a daughter of 222 Rn. We find that 210 Po is out of equilibrium with the other isotopes of the 222 Rn sequence, as we see no evidence of a comparable amount of 210 Bi and all precursors (see below). The solid blue curve is the spectrum obtained after all of the above cuts (i-v) are applied. The spectrum above 100 pe is significantly suppressed by the fiducial cut, by a factor 102 - 103 with exception of the 210 Po peak which is intrinsic to the scintillator. Above the 210 Po peak a clear shoulder is visible with an end point around 380 pe (approximately 750 keV), then the spectrum rises again mainly because of 11 C cosmogenic events. Finally, the solid red curve is the spectrum that is obtained when the 210 Po peak is statistically subtracted using the / discrimination algorithm (Gatti filter). What remains in the region between 7

100 and 400 pe is dominated by 7 Be neutrinos. In spite of the prominent background, the sensitivity of the detector to 7 Be neutrinos is not compromised thanks to the excellent energy resolution and / discrimination. Other spectral components (85 Kr, 39 Ar, 214 Pb, 210 Bi) that may be present are not evident in this figure. We assumed a linear relationship between energy and the number of detected photoelectrons in the limited region of the 7 Be neutrino events. The 14 C spectrum was used to determine the conversion scale, accounting for the expected quenching of low energy electrons. To measure the 7 Be neutrino signal we have followed two independent and complementary analysis approaches, which yielded consistent results. In the first approach (see Fig. 5), events were selected with the additional requirement that the mean time of the hits belonging to the cluster with respect to the first hit of the cluster must be <100 ns. This cut rejects residual muons that were not tagged by the outer detector and that interacted in the buffer (PC+DMP) regions. Some events are removed by this cut too. Also, the exposure used for this analysis was 3058 day · ton. The shoulder in the spectrum between 560 keV and 800 keV was fitted taking into account the expected Compton like shape of the electron recoil spectrum from 0.862 MeV 7 Be neutrinos and the background from 85 Kr and 210 Bi decays. The 85 Kr component was constrained using data from the low energy region, between the 14 C end-point and the 210 Po peak. In addition, the pep neutrino component was fixed to the expected SSM/LMA value and the contribution


from CNO solar neutrinos and from 210 Bi (which are not easily distinguished) were combined as a free parameter. No other background components were included in the final fit because they were found not relevant. As remarked above, background in the fiducial volume and for the range 250­800 keV is lower than 0.5 counts/(day · 100 ton) and therefore is not relevant within the statistics accumulated (13). Moreover, the study of the fast coincidence decay of 214 Bi-214 Po (from 238 U chain) and 212 Bi-212 Po (from 232 Th chain) yields, under the assumption of secular equilibrium, upper limits for 238 U (<2 decays/(day · 100 ton), equivalent to 2â10-17 g/g) and 232 Th (<0.3 decays/(day · 100 ton), equivalent to 7â10-18 g/g). Consequently the contribution to the final spectrum of the background related to 238 U and 232 Th is negligible and was not included in the fit. The shape of the 85 Kr spectrum and that of the 7 Be electron recoil spectrum are similar, and the two components are correlated in fits over the whole spectrum. In the shoulder region the correlation is weaker, thus the 7 Be can be separated from 85 Kr. However, the spectrum cannot be fit with only 85 Kr and this hypothesis is rejected at >5 level. Our lack of knowledge of the real 85 Kr content in the scintillator is one of the ma jor sources of uncertainty, and will be further discussed below. We searched for Kr through the rare decay sequence 85 Kr85m Rb+e- +e , 85m Rb85 Rb+ ( = 1.5 µs, ¯ BR 0.43%) that offers a delayed coincidence tag. Only two candidates were found in the whole scintillator volume, with a corresponding upper limit of <35 counts/(day ·100 ton) (90% C.L.) for dominant 85 Kr -decay branch. In the second analysis approach (see Fig. 6) we performed a statistical subtraction of the 210 Po peak by the following procedure. For each energy bin, the distribution of the Gatti variable was fitted using two gaussian curves, one representing the population, the second one, the population. For each energy bin we fit and separated the two components, thus computing the relative amount of 's and 's. In this way the 210 Po was statistically removed, and the spectral fit could be performed in the whole energy range between 270 keV and 800 keV. The CNO and the 210 Bi were again combined as a single fit parameter. The fit also included a term for a residual 210 Po peak, in order to account for possible inaccuracies in the statistical subtraction. In both fits the statistical error is determined by three independent factors: a) the available statistics; 8

b) the correlation of the fit result with the amount of 85 Kr content; c) the correlation of the fit result with the exact value of light yield. The first factor a) is trivially related to the amount of statistics collected so far; the second factor b) is related to the fact that we currently do not know the exact content of 85 Kr in the scintillator, and no other method but the spectral fit itself could be applied so far. This uncertainty will be reduced by future calibration activities and also by the improved statistics, which will allow an independent measurement of the 85 Kr content via the delayed coincidences. We are also planning to determine the Kr content by direct measurement using mass spectrometry. The third factor c) is due to the fact that our current determination of the light yield was obtained by fitting the upper half of the 14 C decay spectrum. Although the position of the fitted 7 Be shoulder agrees very well with the expected value, the error in the light yield is still significant, and the exact 7 Be content is found to be correlated with the yield itself. The three errors combined in quadrature currently yield a statistical error of 15%. The main source of systematic error is the determination of the fiducial mass. It was determined by rescaling the total number of background events from activities known to be uniformly distributed in the inner vessel to those found within the nominal fiducial volume, and by using the known amount of scintillator loaded into the inner nylon vessel (314.8 m3 , 278.3 ton). In principle this procedure might allow the determination of the fiducial mass with fairly good precision. However, the experimental distribution of the 14 C is found to be nonuniform outside the fiducial volume, a fact that can be explained in part by a non-uniform detector response (light collection, trigger efficiency and other possible effects). Our best estimate of the systematic uncertainty currently associated with the definition of the fiducial mass is 25%. We expect to reduce the uncertainty significantly with an intensive calibration campaign. When all effects are taken into account, our best value for the interaction rate of 0.862 MeV 7 Be neutrinos is: 47 ± 7stat ± 12sys counts/(day · 100 ton) in the full electron recoil spectrum. The first quoted error is 1 statistical, while the second is the maximum systematic error due to the fiducial mass determination. The best value for the 85 Kr rate given by the fit is 22 ± 7 ± 5 counts/(day · 100 ton). The fits also yield a contribution for the sum of 210 Bi 's and the


CNO signal of 15 ± 4 ± 5 counts/(day · 100 ton). The two components cannot be disentangled at this stage and the presence of other background sources to this number cannot be excluded. Thus, the contribution due to the CNO component cannot be extracted from this number. The excellent agreement of the observed spectrum with the expected spectral shape of a monenergetic 0.862 MeV neutrino strongly supports the conclusion that 7 Be solar neutrinos have been detected. We have not identified any background that can fit the spectrum in the region of the 7 Be signal. In particular, a potentially serious background in this energy region is 85 Kr. However, the data are highly inconsistent with the signal arising solely from 85 Kr (the 2 corresponds to a deviation of more that 5 ). 5. Conclusions We have measured the 0.862 MeV 7 Be component of solar neutrino spectrum in the Borexino detector. The best value for the rate is 47 ± 7stat ± 12sys counts/(day · 100 ton). The rate averaged over the earth orbit based on solar models and neutrino oscillations is expected to be 49±4 counts/(day · 100 ton) while the rate expected without oscillations is 75±4 counts/(day · 100 ton) (5; 11). Acknowledgements We sincerely thank the funding agencies: INFN (Italy), NSF (USA), BMBF, DFG and MPG (Germany), Rosnauka (Russia) and we acknowledge the generous support of the Laboratori Nazionali del Gran Sasso. We gratefully acknowledge the valuable contribution from former collaborators. This paper is dedicated to the memory of Cristina Arpesella, Martin Deutsch, Burkhard Freudiger, Andrei Martemianov and Sandro Vitale, and to John Bahcall, a friend and strong supporter of Borexino. References [1] S.Fukuda et al.(Super-Kamiokande collaboration), Phys. Rev. Lett. 86 (2001) 5651; Phys. Lett. B539 (2002) 179. [2] Q.R. Ahmad et al. (SNO Collaboration), Phys. Rev. Lett. 87 (2001) 071301. 9

[3]

[4] [5] [6] [7] [8] [9] [10] [11]

[12] [13] [14] [15]

[16]

[17] [18] [19] [20] [21]

[22]

[23]

F. Confortola et al. (LUNA Collaboration), Phys. Rev. C 75 (2007) 065803 and references therein. J. Bahcall, M. C. Gonzalez-Garcia, and C. Pena-Garay, JHEP 0408 (2004) 016. ~ G. L. Fogli, E. Lisi, A. Marrone, and A. Palazzo, Prog. Nucl. Phys. 57 (2006) 742. A. Friedland, C. Lunardini, and C. Pena-Garay, ~ Phys. Lett. B 594 (2004) 347. R. Davis, Nobel Prize Lecture (2002). W. Hampel et al. (GALLEX Collaboration), Phys. Lett. B 447 (1999) 127. J. N. Abdurashitov et al. (SAGE collaboration), Phys. Rev. Lett. 83 (1999) 4686. M. Altmann et al. (GNO Collaboration), Phys. Lett. B 616 (2005) 174. C. Pena-Garay, talk at the conference ~ Neutrino Telescopes 2007", March 69, 2007, Venice, available online at neutrino.pd.infn.it/conference2007/. G. Alimonti et al. (Borexino Collaboration), Astropart. Phys. 8 (1998) 141. G. Alimonti et al. (Borexino Collaboration), Astropart. Phys. 16 (2002) 205. C. Arpesella et al. (Borexino Collaboration), Astropart. Phys. 18 (2002) 1. A. Pocar, "Low Background Techniques and Experimental Challenges for Borexino and its Nylon Vessels", Ph.D. Thesis, Princeton University (2003). J. Benziger et al., "The Nylon Scintillator Containment Vessels for the Borexino Solar Neutrino Experiment", arXiv:physics/0702162, accepted for publication in Nucl. Inst. Meth. A. A. Ianni et al., Nucl. Inst. Meth. A 537 (2005) 683. A. Brigatti et al,. Nucl. Inst. Meth. A 537 (2005) 521. L. Oberauer et al., Nucl. Inst. Meth. A 530 (2004) 453. Borexino Collaboration, "The Borexino Detector", paper in preparation. H. Simgen and G. Zuzel, Ultrapure gases From the Production Plant to the Laboratory, AIP Conference Proceedings Vol. 897, Topical Workshop on Low Radioactivity Techniques: LRT 2006, Aussois (France), pp. 45­50, ed. P. Loaiza, Springer (2007). J. Benziger et al., "The Scintillator Purification System for the Borexino Solar Neutrino Experiment", paper in preparation. F. Gatti et al., Nucl. Inst. Meth. A 370 (1996)


609. [24] G. Alimonti et al. (Borexino Collaboration), Nucl. Inst. Meth. A 440 (2002) 360. [25] C. Galbiati and K. McCarty, Nucl. Inst. Meth. A 568 (2006) 700. [26] H. O. Back et al. (Borexino Collaboration), "Pulse-Shape discrimination with the Counting Test Facility", arXiv:0705.0239, submitted to Nucl. Inst. Meth. A. [27] H. O. Back, PhD Thesis, Virginia Polytechnic Institute and State University, 2004.

10