Документ взят из кэша поисковой машины. Адрес оригинального документа : http://xmm.vilspa.esa.es/sas/7.0.0/doc/tabgtigen/node4.html
Дата изменения: Wed Jun 28 23:08:31 2006
Дата индексирования: Sat Dec 22 10:45:17 2007
Кодировка:

Поисковые слова: п п п п п п п п п
Parameters XMM-Newton SAS Home Page
XMM-Newton Science Analysis System


tabgtigen (tabgtigen-2.12.3) [xmmsas_20060628_1801-7.0.0]

Description Home Page Errors Home Index

Meta Index / Home Page

Parameters

This section documents the parameters recognized by this task (if any).

ParameterMand Type Default Constraints
tableyesname of existing table input table specifier
a table specifier which must point to a table in a data set. It must be in either of the three forms setname, setname+tableid or setname[tableid] where setname must be the name of an existing data set and tableid an identifier of a table in that data set. If the first form, setname, is used, the table data are sought in the first block of the named data set. tableid can either be an identifier starting with a letter which must then be the name of a table in the specified data set or a simple number which is directly interpreted as a block sequence number (starting from 1).
 
expressionyesstring valid boolean expression according to above syntax rules
the boolean expression controlling the creation of the GTI file
 
gtisetnotable specifiergti.ds:ALLGTInone
The name of the resulting output GTI table - can be the name of an already existing table (which will get overwritten) or the name of a new one in an existing or new data set.
 
timecolumnnostringTIMEname of existing column
name of the column in the input data set containing the time stamps
 
prefractionnoreal0.5-1.0-1.0
the fraction of the previous time interval to be included in the current GTI. A value of 1.0 means to include the whole interval. The default is to take half of the time interval as if the state change occurred between the sample instants. Please note: For the adjustment of the very START time there is no previous time interval to consider - the subsequent one is taken instead.
 
postfractionnoreal0.5-1.0-1.0
the fraction of the subsequent time interval to be included in the current GTI. A value of 1.0 means to include the whole interval. The default is to take half of the time interval as if the state change occurred between the sample instants. Please note: For the adjustment of the last STOP time there is no following time interval to consider - the previous one is taken instead.
 
mingtisizenoreal $>=0$
The output GTI table shall not contain GTIs with durations less than this limit. Its value shall be echoed in attribute MINGTISZ together with a new attribute SUMSHORT (the sum of all GTIs shorter than mingtisize).
 
ParameterMand Type Default Constraints


Description Home Page Errors Home Index

XMM-Newton SOC/SSC -- 2006-06-28