XMM­Newton CCF Release Note
XMM­CCF­REL­93
EPIC MOS HK GTI Selection
D. Lumb
September 26, 2001
1 CCF components
Name of CCF VALDATE List of Blocks
changed
CAL VERSION XSCS flag
EMOS1 HKPARMINT 0007.CCF 1999­12­10 HKPARMINT NO
EMOS2 HKPARMINT 0007.CCF 1999­12­10 HKPARMINT NO
2 Changes
Closes SPR 2179. It sometimes occurs that the HK screening in the pipeline rejects valid time
intervals. The counting mode values in the HK sometimes remain stuck at large values even after
the counting mode is over.Such counting mode intervals do not result in scientific data anyway, and
appear as missing frames, the CCD­specific Good Time Intervals generated by emframes do not
include the counting mode spells. The HK GTIs are redundant in that respect.
The associated HK checks have been removed altogether.
3 Scientific Impact of this Update
Needed to operate correctly the GTI selection functionality