Документ взят из кэша поисковой машины. Адрес оригинального документа : http://xmm.vilspa.esa.es/calibration/documentation/CALHB/node491.html
Дата изменения: Tue Sep 20 19:45:19 2011
Дата индексирования: Mon Apr 11 03:55:41 2016
Кодировка:

Поисковые слова: m 8
Input

Calibration Access and Data Handbook


next up previous contents
Next: Output Up: Calling Parameters Previous: Calling Parameters   Contents

Input
ENERGY
energy at which the effective area will be calculated.
theta
off-axis angle position in the FOCCOORD reference system at which the effective area curve is requested.
phi
azimuth angle position in the FOCCOORD reference system at which the effective area curve is requested.
ORDER
reflection order
BETA
(array) dispersion angle bins (float) at which the LSF has to be evaluated
F_ORDERSEL
fraction of range of the CCD redistribution that has to be considered for the order selection; this is numerical input field that describes the selection efficiency that was use to generate the order selection region.
F_XDSPSEL
fraction of range of the cross-dispersion LSF that has to be considered for the order selection; this is numerical input field that describes the selection efficiency that was use to generate the image selection region.
REGION_ID
the ID of selection regions (order selection & cross-dispersion selection; TBC)



Michael Smith 2011-09-20