Документ взят из кэша поисковой машины. Адрес
оригинального документа
: http://xmm.vilspa.esa.es/calibration/documentation/CALHB/node454.html
Дата изменения: Tue Sep 20 19:45:19 2011 Дата индексирования: Mon Apr 11 03:04:08 2016 Кодировка: Поисковые слова: р п р п р п п р п п р п п р п п р п п р п п р п п р п п р п п р п |
The grating mis-alignment is parameterized with a set of Gaussian
functions, whose parameters are stored in the CCF. The corresponding
probability density is according to
The parameters , , are stored in the CCF.
is the number of parameters available in the CCF. is the chromatic
magnification that scales the width of the grating mis-alignment
distribution as a function of angle of incidence and diffraction
angle. It is defined as
Additionally to the chromatic magnification, the alignment distribution is homogeniously scaled by a factor , which is stored in the CCF.
The average center of all Gaussians is calculated by
The function returns the probability distribution which
calculated from by integration per channel
The distribution will be calculated such that the peak is at the center of the bins.