Документ взят из кэша поисковой машины. Адрес
оригинального документа
: http://www.stsci.edu/smov/notes/0507smov.html
Дата изменения: Fri May 9 00:59:08 1997 Дата индексирования: Thu Feb 27 23:57:07 2014 Кодировка: Поисковые слова: orion nebula |
STIS SMOV update 1. NUV MAMA high voltage test, Wed. 7 May Things were looking nominal at the intermediate voltages and for at least 4 minutes of high voltage, when telemetry was lost per the schedule. When reacquired, the telemetry indicated high voltage off because of the global count rate monitor had been exceeded. The team is studying ESS extractions to see what actually happened during the telemetry drop out. Meanwhile an alternate SMS132, that includes a repeat of this NUV hv test early next week, is being readied. 2. CCD peak-ups. This week's failure of the 7071 peak-up was due in part to the known elevated bias level, in the acq subarray, that skewed the flux-weighted centroiding algorithm. The ~ 1-hour separation between the acq and the peak-up, on one guide star, didn't help either. There are plans at least to salvage the 7147 CCD Fine Alignment by adjustment of some parameters used in the acq algorithm so that this activity can proceed as planned in next week's SMS. Whether the STIS observations in the SMS139 need any adjustments to make them work is still under investigation. - Carl
Go back to the Meeting Minutes Page