Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.stsci.edu/instruments/wfpc2/Wfpc2_hand4/ch8_calibration9.html
Дата изменения: Tue Sep 4 21:44:47 2001
Дата индексирования: Sat Dec 22 20:32:20 2007
Кодировка:

Поисковые слова: п п п п п п п п п п п п п п п п п п р п
Fluxes and Standard Magnitudes
STScI

WFPC2 Instrument Handbook for Cycle 11

TOC PREV NEXT INDEX

Fluxes and Standard Magnitudes


The pipeline calibrated data are not flux calibrated and the data are in units of Data Numbers (DN). However, a flux calibration is supplied in the header keywords. To obtain the flux density, multiply DN by the value of the keyword PHOTFLAM in the calibrated (.c0h) science header file, and divide by the value of the keyword EXPTIME.

The magnitude of an object can be determined using the photometric zero-point keyword PHOTZPT as :

where m is in the STMAG system which is based on a spectrum with constant flux per unit wavelength set to roughly match the Johnson system at V. The more conventional systems are based on Vega's spectrum. Table 8.2 was generated using SYNPHOT to provide rough conversions from STMAG to the Johnson UBVRI and Cousins RI systems. Typical uncertainties are 5%, and probably much worse for the U filter. The correction depends on the spectrum of the object, hence the table was generated using a wide range of Bruzual models.

For example, to convert to the Cousins I band for an object on WF4, get PHOTZPT=-21.1 and PHOTFLAM=2.6044 x 10-18 from the header. Then convert from WFPC2 counts to magnitudes in Cousins I using:

Note that the Cousins I filter is much closer to the F814W filter than Johnson I, as shown by the nearly constant correction as a function of spectral type (i.e. color term).
Table 8.2: Conversion from STMAG to Johnson UBVRI and Cousins RI.

U-F336W B-F439W V-F555W RJ-F675W IJ-F814W RC-F675W IC-F814W
O5V
0.53
0.67
0.05
-0.67
-1.11
-0.71
-1.22
B0V
0.46
0.66
0.05
-0.67
-1.13
-0.70
-1.22
A0V
-0.08
0.67
0.02
-0.68
-1.22
-0.67
-1.21
F2V
-0.03
0.62
-0.00
-0.69
-1.28
-0.63
-1.22
G0V
-0.02
0.58
-0.01
-0.70
-1.31
-0.60
-1.23
K0V
-0.10
0.53
-0.01
-0.69
-1.32
-0.58
-1.23
M0V
-0.04
0.43
-0.00
-0.78
-1.48
-0.54
-1.22
M6V
0.05
0.29
-0.03
-1.05
-1.67
-0.56
-1.21

 

This procedure will provide typical accuracies of about 0.05 mag, worse in the UV. More accurate photometry will require a variety of corrections (e.g., CTE effect, contamination and red leaks for the UV filters, variable gains on different chips, color terms, geometric distortions) which are discussed in detail in Holtzman et al. (P.A.S.P., 1995b) and in the HST Data Handbook.


Space Telescope Science Institute
http://www.stsci.edu
Voice: (410) 338-1082
help@stsci.edu
TOC PREV NEXT INDEX