Документ взят из кэша поисковой машины. Адрес
оригинального документа
: http://www.stsci.edu/instrument-news/handbooks/wfpc2/W2_23.html
Дата изменения: Wed Jul 24 04:09:03 1996 Дата индексирования: Tue Feb 5 06:02:08 2013 Кодировка: Поисковые слова: п п п п п |
The filter complement includes two solar blind Wood's filters, F160AW and F160BW. F160BW is used in all science observations because the other filter has some large pinholes that lead to significant red leak.
In addition to the above complement of broad and narrow-band filters, WFPC2 features a set of three specialized quadrant (quad or Q) filters in which each quadrant corresponds to a facet of the pyramid, and therefore to a distinct camera relay. There is one quad containing four narrow-band, redshifted [OII] filters with central wavelengths from 3763Å to 3986Å, one quad with four polarizing elements (POL) with polarization angles, 0 degrees , 45 degrees , 90 degrees and 135 degrees , and one quad with four methane (CH4) band filters with central wavelengths from 5433Å to 8929Å. The polarizer quad filter can be crossed with any other filter over the wavelength range from 2800Å to 8000Å, with the exception of the Methane Quad and Redshifted [OII] Quad which share the same wheel. The SOFA also contains four linearly variable narrow-band ramp (FR) filters (in the twelfth wheel - closest to the focus). The quad and ramp filters are listed in Table 3.2
In Table 3.1 and Table 3.2, each of the type "A" filters is equivalent to inserting 5 mm of quartz in terms of optical path length, with compensation for wavelength such that focus is maintained on the CCDs. A configuration with no filters in the beam results in out-of-focus images and generally will not be used. With the exception of the quad polarizer and blocking (Type "B") filters, all filters are designed to be used alone. Type "B" filters introduce no focus shift, so they can be used in combination with any type "A" filter. All combinations where the number of type "A" filters is not unity will result in out-of-focus images. The image blur resulting from two or zero type "A" filters at visible wavelengths is equivalent to 2.3 mm defocus in the F/24 beam, which corresponds to 1/5 wave RMS of defocus at 6328Å, and a geometrical image blur of 0.34" . While this is a large defocus, the images are still of very high quality compared to seeing limited images. Some such combinations may be scientifically attractive. For example, the Wood's filter may be crossed with another UV filter to provide a solar blind passband (although the efficiency will be low).
Table 3.1: WFPC2 Simple Filter Set. The effective wavelength, width,
and transmission quoted are defined precisely in Chapter 6,
but here are quoted without the system (OTA_WFPC2) response.
The mean wavelength,
, is similar to that defined in Schneider, Gunn and Hoessel (Ap. J. 264, 337). The width is the FWHM of a Gaussian filter with the same second moment, and is reasonably close to the FWHM. The values tabulated here do not include the CCD DQE or the transmission of the OTA or WFPC2 optics (as given in Figure 2.4). In Chapter 6, the corresponding quantities are given including the effect of the other optical elements and the CCD DQE.
Table 3.2: WFPC2 Quad and Ramp Filters. Segments of the UV and CH4
quads are labeled here by their usual physical designations (A, B, C, and D);
see following sections for filter and aperture names which are to be used
in writing Phase II proposal. The quad polarizer is represented for both
parallel and perpendicular polarization to its polarization direction,
which is different in each quadrant.
Figure 3.1
A passband calibration is maintained in the calibration database system (CDBS). It has been updated following on orbit calibrations. The ground based calibration of the narrow-band filters' central wavelengths has not been corrected for temperature effects and is therefore accurate to about 2Å. Because of this, it is not advisable to place narrow emission lines at the half power points of such filters and expect to predict the throughput to high accuracy. The standalone software package XCAL, or SYNPHOT running under IRAF, can be used to access these calibrations which are available on the Institute's WWW page.
Figure 3.1: Summary of Normalized Filter Curves