The FGS PMTs (four per FGS) are end-illuminated, 13 stage venetian blind dynode S-20 photon-counting detectors with an effective photocathode area of about 4 mm. The A and B channels for each FGS interferometric axis operate independently. The PMTs are sensitive over a bandpass of 4000-7000A, with an efficiency of ~ 18% at the blue and diminishing linearly to about 2% at the red end.
With HSTs 0.23 microns of spherical aberration, a decentering of the wavefront by only 0.25 mm will decrease the modulation of the S-Curve to 75% of its perfectly aligned value. If the telescope were not spherically aberrated (i.e., if the wavefront were planar) misalignments up to five times this size would hardly be noticeable. The impact of HST's spherical aberration and the improved performance of FGS1r are discussed in Chapter 2 of the FGS Instrument Handbook.