FGS Instrument Handbook for Cycle 24 |
help@stsci.edu |
The FGS has two modes of operation: Position mode and Transfer mode. In Position mode the FGS locks onto and tracks a star’s interferometric fringes to precisely determine its location in the FGS FOV. By sequentially observing other stars in a similar fashion, the relative angular positions of luminous objects are measured with a per-observation precision of about 1 mas over a magnitude range of 3.0 < V < 16.8. This mode is used for relative astrometry, i.e., for measuring parallax, proper motion, and reflex motion. Multi-epoch programs have achieved accuracies of 0.2 mas or better (1-sigma).As a science instrument, the FGS is a sub-milliarcsecond astrometer and a high angular resolution interferometer. Some of the investigations well suited for the FGS are listed here and discussed in detail in Chapter 3:
• Relative astrometry (position, parallax, proper motion, reflex motion) with single-measurement accuracies of about 1 milliarcsecond (mas). Multi-epoch observing programs have determine parallaxes with accuracies of 0.2 mas and better.
• Measurement of the angular diameters of non-point source objects down to about 8 mas.