The previous section made reference to the pixel-based model of CTE losses. The WFC3/UVIS model is based on the empirical model that was constructed by Anderson & Bedin (2010), which itself was inspired by the model in Massey et al. (2010) for ACS/WFC.In order to determine the model parameters, we examined the blurring experienced by hot and warm pixels in a variety of dark exposures taken in August 2012 with both short (100s) and long (900s) exposure times, and with various post-flash background levels (from zero up to 60 electrons). In practice, the model was constrained by first solving for the pre-readout distribution of warm pixels from the long-dark exposures, then fitting the trailed model to the trailed short-dark observations. The variety of background levels provided additional constraints. The first set of parameters (the distribution of traps as a function of charge-cloud size) is shown in Figure 6.1.