G. Morgante and F. Pasian
Osservatorio Astronomico di Trieste, 34131 Trieste, Italy
Email: pasian@ts.astro.it
P. Ballester
European Southern Observatory, D-85748 Garching, Germany
The pipeline reduction is based on an accurate set of ``pre-calibrated solutions" and will also result in a powerful tool for the release and the distribution of the scientific data, from a simple quick look at the data just collected to a complete echelle reduction with the highest possible accuracy.
It is ESO policy to perform data reduction for VLT instruments in ``pipeline" mode, either at the observing premises or at headquarters. The result of the pipeline will be a ``standard quality" data product, certified by the Observatory.
In order to verify if a pipeline was feasible for echelle data, in particular for UVES (Ultraviolet-Visible Echelle Spectrograph), a test on EMMI (ESO Multi-Mode Instrument) data acquired in echelle mode and extracted from the NTT archive was performed:
The key points of the work were identified to be the following:
The MIDAS environment, and in particular its Echelle Package, include proper tools for building pipeline DRS for generic echelle instruments, and in the future for UVES, with some minor improvements. In the pipeline built for EMMI, pre-calibrated solutions (i.e., tables containing the results of interactive processing on selected ``reference" spectra) were used for order detection and wavelength calibration as starting points. The UPDATE/ORDER MIDAS command was used to re-define the positions of the orders starting from the pre-calibrated order table.
The wavelength calibration has been performed using IDENT/ECHELLE with the GUESS method (i.e., searching for the optimal solution starting from a pre-defined position of calibration lines). The result was accepted only after checking the plot of residuals and the ``percentage of identification among the half brighter lines", that should be the highest, and in any case above 50%.
The analysis of applicability for the pre-calibrated solutions has verified that, for a stable instrumental configuration and performance, the current procedures are quite adequate. Minor software upgrades could be made to take care of extreme situations; e.g., for EMMI a non-rigid shift in order positions due to a changed field lens was corrected with a custom modification of the UPDATE/ORDER command. A new set of pre-calibrated solutions shall however be computed by staff whenever a manual intervention on the instrument is made; such interventions shall be appropriately reported in the archive. New pre-calibrated solutions should be computed during every test period, to minimize a-posteriori software recovery.
For an efficient quality control to take place, the setup of proper operational procedures is necessary:
In this work, it was decided to rely uniquely on the contents of the archive and of the keywords of the files, because this is the standard approach an ESO user would take in accessing data he/she would have not acquired directly. In accordance with the results of Péron et al. (1994), some incompleteness in the archive of EMMI echelle data has been identified. In the future, for EMMI but especially for UVES, the following are key items for archive completeness:
The work has been carried out under ESO Contract No. 47980/DMD/96/7513 to OAT. Useful information and valuable suggestions were provided during meetings at ESO by H.Dekker, S.d'Odorico, H.Hernsberge, R.Gilmozzi, P.Grosbøl, L.Kaper, B.Leibundgut, P.Molaro, P.Nielsen, and L.Pasquini. Useful discussions with P.Bonifacio and S.Monai of OAT are gratefully acknowledged.
Ballester, P. 1992, in Proc. 4th ESO/ ST-ECF Data Analysis Workshop, ESO Conf. and Workshop Proc. No. 41, 177
Ballester, P., Rosa, M. R. 1997, Astr. Astroph., in press, ESO Scientific Preprint No. 1220
Morgante, G., Pasian, F. 1997, Feasibility Study of Pipeline and Quality Control Software for Echelle Data - Final Report, OAT Technical Report
Péron, M., Albrecht, M. A., Grosbol, P. 1994, in Proc. ESO/OAT Workshop Handling and Archiving Data from Ground-based Telescopes, M.A.Albrecht & F.Pasian eds., ESO Conf. and Workshop Proc. No. 50, 57
Verschueren, W., Hernsberge, H. 1990, in Proc. 2nd ESO/ST-ECF Data Analysis Workshop, ESO Conf. and Workshop Proc. No. 34, 143