Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.sao.ru/Doc-en/Science/results/ar_facil/res2002.html
Дата изменения: Unknown
Дата индексирования: Sun Apr 10 17:26:31 2016
Кодировка:

Поисковые слова: р р р с р с р р р с р с р р р с с р р п п п п п п п п п п п п
Hardware sector, archive 2002
Logo (Main page)
Special Astrophysical Observatory RAS

Russian
   About us      Divisions     Telescopes     Science     Publications     Education     Service     Contacts  

Scientific achievements, Hardware and methodical developments

 2002: 


A quartz echelle spectrograph with a large diameter of the collimated beam (NES) equipped with a CCD (2048x2048 elements) was designed, manufactured and put into operation in the Nasmyth focus of the 6-m telescope. The spectrograph provides the spectral resolution of up to R=82000 in the wavelength range of 320-1000nm. The information content of observations with high spectral resolution at the telescope is increased tenfold.
In collaboration with the University of Uppsala (Sweden)


A new-generation CCD system with the cryostat matrix detector sized 2048x2048 elements was designed and put into operation at the 6-m telescope. Digital video signal filtering and correction of the light transmission characteristics were implemented for the first time. This provides the limiting sensitivity and photometric stability for the astronomical practice. The readout noise is reduced by 30-40% compared with the traditional methods of data reduction (with the EEV CCD42-40 - 1.7 electrons). The residual nonlinearity does not exceed 0.03%, and relative photometric instability does not exceed 0.06% over 24 hours. Production of such systems with the CCD42-40 for the 6-m telescope is tailored.
In collaboration with the Institute of Applied Physics of the RAS


We have developed and tested the model of a new-generation three-element broadband radiometric matrix system at the RATAN-600 extremely short wavelength of 1 cm, allowing a large replication to over 100 elements. The sensitivity of 6mK reached without cooling is close to the sensitivity of the cryogenic radiometers of the RATAN-600 in the given range.


New electrodynamic calculations of the RATAN-600 power beam pattern, including the diffraction effects and the account of the finite size width of the primary mirror aperture are in good agreement with the experimental measurements over a wide wavelength range and a large solid angle, conducted in 2002. These measurements and the power beam pattern calculation programs increase the accuracy of measurements of the flux densities and radio brightness distributions of extended cosmic sources, and are used in the data processing and modeling of the recent and future radio surveys featuring the radio source counts, and in the studies of the anisotropy of the cosmic microwave background.


Creation of a basic high speed Ethernet information computer network of the SAO RAS has been accomplished. It now provides access to the BTA and RATAN-600 telescopes at 155 Mbit/s based on the 27 km-long fiber optic link. The outgoing Internet speed reached is 2 Mbit/s.


  Back to previous page Archive


Any questions to  webmaster 
Last update: 20/02/2013