ALFA Receiver Temperature Polynomial Fit

ALFA Receiver Temperature Polynomial Fit
A. Deshpande (30 Sept. 2004)

Note: These models for T-receiver are based on measurements for all of the 14 pipelines.

download Trx polynomial fit parameters

The first line of this file consists of entries defining

The rest of the above entries (from line 2 and onward) corresponding to each model fit refer to the following (in that sequence).

Note that the order in which the various model sets are listed above is not important, though useful. Results of more than one set of measurements can be listed above, and the subsequent interpreting code should be able to combine them suitably to obtain improved estimates of the relevant parameter ( 1/[rms**2] weighting is recommended). An example of such a code is fetch_from_best_fit_model.f made available for your use.