Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.naic.edu/~phil/hardware/lr/trlaser/LLB60D-A-1-GB-1.pdf
Дата изменения: Wed May 11 18:19:02 2011
Дата индексирования: Tue Feb 5 10:27:27 2013
Кодировка:

Поисковые слова: http www.astronet.ru
Laser Measuring Device LLB-60-D (H)

i
· · · · ·

Eglishalde 6 D-78647 Trossingen Tel. +49 - (0) 74 25 / 228 - 0 Fax +49 - (0) 74 25 / 228 - 33 http://www.tr-electronic.de Germany

Analog interface: 0...20 mA or 4...20 mA RS232 -, RS422 - interface Detection of positions Non contact distance measurement Distance measurements on - natural surfaces : 0.05 up to approx. 65 m - reflective target plate : 0.05 up to approx. 500 m · LLB60-00600, LLB60-00601: without heating · LLB60-00610, LLB60-00611: with heating · Programmable

Characteristics
Supply voltage........................................................................ 9...30 VDC with heating...................................................................... 24...30 VDC Current consumption without load ......................................... < 0.5 A with heating...................................................................... < 2.5 A Measuring range on natural surfaces .......................................................... typically 0.05...65 m on reflective target plate .................................................. typically 0.05...500 m Smallest unit displayed .......................................................... 0.1 mm Measuring accuracy LLB60-00600, LLB60-00610............................................ typically ± 1.5 mm at 2 LLB60-00601, LLB60-00611............................................ typically ± 3.0 mm at 2 Time for a measurement Single measurement ........................................................ typically 0.15...4 s Tracking Mode ................................................................. typically 0.15...4 s Light source............................................................................ Laser diode, red light Wavelength ................................................................... 620...690 nm Laser protection class ...................................................... 2 accor. IEC 60 825-1: 2001 / FDA 21CFR 1040.10 und 1040.11 Beam divergence ............................................................. 0.16 x 0.6 mrad Pulse duration .................................................................. 0.45 x 10 s Radiant power.................................................................. < 0.95 mW Life time ........................................................................... > 50.000 h at 20 °C Analog interface
1) -9

.................................................................. 0...20 mA, 4...20 mA, 500

Configuration interfaces ......................................................... RS232 Point to Point, RS422 Master ­ Slave, max. 10 devices Digital switching outputs......................................................... Open Drain, 30 VDC, 200 mA 2 Digital outputs for level control ................................... programmable 1 Digital output ................................................................. Device error Digital input
1) 1)

......................................................................... external triggering

Switching level ................................................................. 1-level > +9V...< +30 V, 0-level < 2 V Mass....................................................................................... 665 g, 690 g with heating
1)

programmable parameter

05/07

Revision 00

LLB60D-A-1-GB-1-00.DOC

1 LLB60D-A-1-GB-1

Subject to change

©TR-Electronic GmbH


Eglishalde 6 D-78647 Trossingen Tel. +49 - (0) 74 25 / 228 - 0 Fax +49 - (0) 74 25 / 228 - 33 http://www.tr-electronic.de Germany

Laser Measuring Device LLB-60-D (H)

Environmental conditions
EMC - Discharge of static electricity, DIN EN 61000-4-2: 2001 - Immunity to disturbance, DIN EN 61000-6-2: 2001 - Emission, DIN EN 61000-6-4: 2001 Working temperature ............................................................. -10 °C...+50 °C, max. +45 °C in Tracking Mode Working temperature with heating ......................................... -40 °C...+50 °C, max. +45 °C in Tracking Mode Storage temperature.............................................................. -40 °C...+70 °C, dry Protection class, DIN EN 60529: 1991 ............................... IP 65
2) 2)

valid with screwed on mating connector and / or screwed together cable gland

Dimension drawing

2 LLB60D-A-1-GB-1

LLB60D-A-1-GB-1-00.DOC

05/07

Revision 00

©TR-Electronic GmbH

Subject to change