Description
The PowerCommand Network Annunciator is a network component that provides remote system status indication for emergency and other power systems in compliance to the requirements of NFPA 110. The Network Annunciator may also be used for remote indication of any condition that is monitored by a PowerCommand network. The Network Annunciator reduces installation costs and improves design flexibility by use of a PowerCommand Network to transmit all the genset and transfer switch system signals rather than using relay contacts for this purpose. Control power for PowerCommand network products is usually derived from the generator set starting batteries. The control functions over a voltage range from 8VDC to 35VDC.

Features
· · Visual Indication of 20 Network Conditions and Network Status. Audible Indication of Any Network Condition. Annunciator also includes pushbutton switch to silence the audible alarm. Alarm horn sound level is approximately 90dBA at 30 cm. Standard NFPA110 Label, field configurable for other alarm and status conditions. Configurable for compliance to NFPA99 requirements. Sealed Membrane Panel Design provides environmental protection for internal components and is easy to clean. Warranty. PowerCommand Controls are supported by a worldwide network of independent distributors who provide parts, service and warranty support. UL Listed and Labeled; CSA certified; CE Marked. Wall Mount NEMA 1 Enclosure or Flush Mount configurations available

· · · ·

· ·



2003 Cummins Power Generation.

Specifications May Change Without Notice

S-1343d (9/03)


.

Specifications
Signal Requirements
Network Connections: Echelon LONWORKS®, twisted-pair 78 kbps, FT-10 Control Power: 8-30VDC, 3.5W (maximum) 0.8W typical. Wiring materials for network signals are ULlisted 4 twisted pair wiring. Terminations for control power accept wire up to 16ga.
®

Alarm Horn
Sound Level: 90 dB @ 30cm.

Physical
Weight: 3.2 lbs. (1.45 kg) (board plus enclosure)

Power
Maximum Consumption: 5 watts Standby Consumption: 0.4 watt or less

Environment
The annunciator is designed for proper operation in ambient temperatures from ­40C to +70C, and for storage from ­40C to +80C. Control will operate with humidity up to 95%, non-condensing, and at altitudes up to 13,000 feet (5000 meters).

Network Length: Maximum 4600 Feet (1400M),
when using NEMA Level 4 cable.

Self-binding Configurations:
Supports use of up to four annunciators with up to one generator set and one transfer switch.

Maximum Wire Lengths (Control Power-self-binding system) Wire Size 12VDC 22 ga 330ft. (100M) 20 ga 520 ft. (158M) 18 ga 820 ft. (250M) 16 ga 1300 ft. (398M) 14 ga 2070 ft. (631M)

24VDC 1100 ft. (338M) 1760 ft. (537M) 2790 Ft. (852M) 4430 Ft. (1352M) 4600 Ft. (1400M)

Dimensions
Cut-Out Detail (without enclosure) Annunciator Enclosure Dimensions



2003 Cummins Power Generation.

Specifications May Change Without Notice

S-1343d (9/03)


.

Label Configurations & Standard Bindings
NFPA110 GenSet Alarm and Status Annunciator
The · · · · · · (A) The · · · · · · (A) The · · · (A) The · · · (A) following conditions are provided as High Battery Voltage (A) · Low Battery Voltage (A) · Generator Running (G) · Genset Supplying Load (G) · Pre-Low Oil Pressure (A) · Low Oil Pressure (R) · = Amber; (R) = Red; (G) = Green following conditions are provided as Check Genset (R) · Ground Fault (A) · High AC Voltage (R) · Low AC Voltage (R) · Under Frequency (R) · Overload (R) · = Amber; (R) = Red; (G) = Green following conditions are provided as Check Genset (A) · Genset Supplying Load (A) · Genset Running (G) · = Amber; (R) = Red; (G) = Green standard on the annunciator: Pre-High Coolant Temperature (A) High Coolant Temperature (R) Low Engine Temperature (A) Overspeed (R) Fail to Start (overcrank) (R) Not in Auto (R) · · · · · Battery Charger Malfunction (A) Low Fuel (A) Low Coolant Level (R) Spare (4) (G) Common Alarm

Extended GenSet Alarm and Status Annunciator
standard on the annunciator: Over current (R) Short circuit (R) Reverse KW (R) Reverse kVAR (R) Fail to Sync (A) Fail to Close (R) · · · · · Load Demand (G) Genset CB tripped (R) Utility CB tripped (R) Emergency Stop (R) Spare (4) (G)

8-Point (Genset)
standard on the annunciator: Not in Auto (G) High/Low Engine Temp (G) Low Oil Pressure (A) · · · Low Coolant Level (R) Low Fuel Level (A) Spare (8) (G)

4-Point (Genset)
following conditions are provided as standard on the annunciator: Check Genset (A) · Not in Auto (G) Genset Supplying Load (A) · Spare (16) (G) Genset Running (G) = Amber; (R) = Red; (G) = Green ditions are provided as Fail Fail Fail Low Low to Close to Disconnect to Synchronize Battery-Controller Battery-Network

ATS-Extended
This annunciation set is often used with PLT-series equipment. The following con standard on the annunciator: · Source 1 Available (G) · ATS Not in Auto · · Source 2 Available (G) · Test/Exercise · · Source 1 Connected (G) · Transfer Pending · · Source 2 Connected (G) · Load Shed · · Check ATS (R) · Transfer Inhibit · (A) = Amber; (R) = Red; (G) = Green

ATS 8-Point
The · · · (A) The · · (A) following conditions are provided as Source 1 Available (G) · Source 2 Available (G) · Source 1 Connected (G) · = Amber; (R) = Red; (G) = Green standard on the annunciator: Source 2 Connected (G) Common Alarm (A) Not in Auto (R) · · · Test/Exercise Mode (A) Low Control Battery (A) Spare (8) (G)

ATS 4-Point
following conditions are provided as standard on the annunciator: Source 1 Available (G) · Source 2 Connected (G) Source 2 Available (G) · Source 1 Connected (G) = Amber; (R) = Red; (G) = Green



2003 Cummins Power Generation.

Specifications May Change Without Notice

S-1343d (9/03)


.

Custom Alarm Configuration
# 1 2 3 4 5 6 7 8 9 10
Color (R/A/G)

Label

Horn (Y/N)

# 11 12 13 14 15 16 17 18 19 20

Color (R/Y/G)

Label

Horn (Y/N)

Ordering Information
Part Number
0541-0814-01 0541-0814-02

Description
Network annunciator, open construction, for panel mounting. Network annunciator including control box for surface wall mounting

See your distributor for more information

Cummins Power Generation 1400 73rd Avenue N.E. Minneapolis, MN 55432 763.574.5000 Fax: 763.574.5298 www.cumminspower.com
Cummins Power Generation is a subsidiary of Cummins Inc. PowerCommand is a registered trademark of Cummins Inc. Echelon and LONWORKS are registered trademarks of Echelon. For Professional Use Only. Must be installed by a qualified service technician. Improper nstallation presents hazards of electrical shock and improper operation, resulting in severe personal injury and/or property damage.



2003 Cummins Power Generation.

Specifications May Change Without Notice

S-1343d (9/03)