measured_operating_values

Measured operating values

23oct15

  
The table below contains the measured meter and drive values while tx's were in use.

Columns/abbreviations:


expected meter values when running at 100KW (from manual)

dates:

Notes:



To add more entries: edit and insert (vi) operating_value_template_insert.html at commented insertion point.
pink color is : Value out of specified range



tx
otx

date
S/D


drv
dbf
pwr

RP
FP/
RP
BB
W
Tube
elements

IPA DRVR
PA
KW
dbm
V
I
V
I
V
I
5


151021
dmyLd



-3.6
90



16.8



Fila V/A          
         
        
         
        
         
cGrid V/mA



-300

scrGrid mA xx

xx

xx

cath A xx

xx

xx
18.4
 
5



151022
sky



-3.25
83



16.5
30
25.
225
Fila V/A        
        
       
        
       
        
cGrid V/mA



-380?

scrGrid mA xx

xx

xx

cath A xx

xx

xx
15
 
1

15
151022
sky



-7
87



16.7
35
23.
122
Fila V/A        
        
       
        
       
        
cGrid V/mA



-300

scrGrid mA xx

xx