Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.mrao.cam.ac.uk/projects/OAS/pmwiki/uploads/MROIDelayLine.InterfaceControl/INT-406-VEN-0008.pdf,1244027538
Дата изменения: Fri Aug 17 12:32:34 2007
Дата индексирования: Sat Mar 1 04:17:54 2014
Кодировка:

Поисковые слова: edge-on galaxy
MRO Delay Line ICD

Delay Line to Beam Relay System ICD INT-406-VEN-0008

The Cambridge Delay Line Team

rev 0.1 10 August 2007

Cavendish Laboratory JJ Thomson Avenue Cambridge CB3 0HE UK


1

ICD Description
Sub-systems Delay line Beam Relay system Org UoC Owner MF Brief description and preliminary contents Defines the mechanical interface between the delay line pipe and the beam relay pipe. · Requires one drawing of the complete face-plate and the specified flange arrangement

Specific entry from the ICD N2 Table contained in FDR document:

ICD Number INT-406VEN-0008

2

Change Record

Revision Date Authors Changes 0.1 2007-08-10 MF First draft version

Notification List
The following people should be notified by email that a new version of this document has been issued: MROI: Fernando Santoro UoC: Chris Haniff David Buscher Martin Fisher

2


Table of Contents
1 2 3 4 5 6 7 8 9 10 11 ICD Description ........................................................................................................................... Change Record ............................................................................................................................. Notification List ........................................................................................................................... Scope ............................................................................................................................................ Acronyms and Abbreviations....................................................................................................... Applicable Documents ................................................................................................................. Reference Documents .................................................................................................................. Introduction .................................................................................................................................. Requirements ............................................................................................................................... Design ...................................................................................................................................... Appendix .................................................................................................................................. 2 2 2 3 3 3 3 4 4 4 4

4

Scope

This document details the flange fitting requirements for the beam relay pipe. It does not describe or detail the science window and protection mechanism which would replace the beam relay pipe when it is removed from the delay line pipe.

5
BCA BCF BRS DL DLA ICD ICS SCS

Acronyms and Abbreviations
Beam Combining Area Beam Combining Facility Beam Relay System Delay Line Delay Line Area Interface Control Document Interferometer Control System Supervisory Control System MROI Magdelena Ridge Observatory Interferometer UoC University of Cambridge NMT New Mexico Tech OPD Optical Path Delay TBC To be confirmed TBD To be determined

6

Applicable Documents

DRAWINGS

Specific interface drawings(s): ­ For this initial version of the ICD diagrams are included in the appendix of this document.

7
RD1 RD2 RD3 RD4 RD5

Reference Documents
Delay line to BCF infrastructure (building) (INT-406-VEN-0009) Delay line to metrology system (INT-406-VEN-0010) Metrology System to BCF (INT-406-VEN-0012) Metrology System to Beam Relay System (INT-406-VEN-0013) BCF Area (M3 architectural drawing (AR100) 3


8

Introduction

The interface between the delay line pipe and the beam relay pipe is at the end-plate of the delay line pipe closest to the metrology system. For each delay line the beam relay pipe connects to the end-plate via flange arrangement around the upper science aperture. The flange arrangement allows for removal of the beam relay pipe and its temporary replacement with a science grade window to allow the delay line to be evacuated and operation to be resumed. The temporary window will have a compatible flange fitting and will also be fitted with a fail-safe closing device to protect the delay line in the event of a catastrophic window failure. The beam relay pipe should incorporate a compliant coupling to ensure that undue stresses and vibrations are not transmitted to the delay line pipe.

9

Requirements
1. The interface flange on the DL end-plate should be of sufficient diameter to accommodate the six inch diameter beam relay pipe without obstructing the returning science beam or fouling the science beam or metrology window mounts. 2. The method of coupling the beam relay pipe to the DL interface flange must provide good vacuum sealing whilst allowing the pipe to be easily unbolted, removed and replaced by the protective window. 3. There should be sufficient access to the interface area to allow personnel to uncouple the pipe without disturbing the metrology system on the optical table which is immediately below the pipe and in front of the DL pipe. This requirement also impinges on other ICDs described in RD1, RD2, RD3 and RD4. 4. The transmission of vibrations, which may be induced in the beam relay pipe from disturbances outside the building, must be minimised. 5. Undue stresses due to thermal expansion/contraction of the beam relay pipe or the length of delay line pipe between the anchor and the BCF area should not be imposed on the delay line.

The requirements of the interface are:

10 Design
The space available for a flange fitting is very limited. In addition space must be made available to mount a protection mechanism over the lower science window. An interface `stub' of length [TBD] provides a flange to which the beam relay pipe can be fitted see Figure 1. The space in front of this flange and around the beam relay pipe is also limited by the requirements of the metrology system and is defined in RD4. A 7 inch overall diameter flange is the largest that can be accommodated and this limits the outside diameter of beam relay pipe that can be used to 6 inches. The flange dimensions and fixing details are shown in Figure 2. The length of the interface stub will be determined by the size of window protection mechanism.

11 Appendix
Figure 1: A 3-D view of the delay line pipe end-plate with the flanged stub fitted. Figure 2: Flange dimensions and fixing details. 4


Figure 1 A 3-D view of the delay line pipe end-plate with the flanged stub fitted.

5


Figure 2 Flange dimensions and fixing details. 6