Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.ipa.nw.ru/conference/wpltn2012/docs/24/1300%20fedotov.pdf
Дата изменения: Mon Oct 1 11:59:46 2012
Дата индексирования: Sun Feb 3 17:52:33 2013
Кодировка:

Поисковые слова: spring
System for high-accuracy determination of ephemeris and time corrections (SVOEVP) GLONASS
A.Yu. Suslov, E.V. Titov, A.A. Fedotov, V.D. Shargorodskiy

International conference «One- and two-way SLR in collocation with radio systems for GNSS» 24-27 September 2012 IPA RAS, St. Petersburg


Global Navigation System GLONASS
Federal Target Program «Global Navigation System»

Orbital constellation
,
35 30 , 25 20 15 10 5 0 1990

Navigation field accuracy
35 30 25 20 15 10 5 0 1980 1983 1986 1989 1992 1995 1998 2001 2004 2007 2010 2013

1992

1994

1996

1998

2000

2002

2004

2006

2008

2010



GPS



GPS

2


Ways to improve navigation services
1. Improvement of accuracy of S/C motion models and measurements interpretation used for calculation of ephemeris and time information (ETI). 2. Improvement of accuracy of geodetic support for the Ground Control System (GCS). 3. Formation and transmission of ETI accuracy factor within navigation message. 4. Implementation of assistive technologies for accredited users. 5. Correction of errors due to frequency division of GLONASS navigation signals by calibration of user navigation equipment.
3


Purpose of SVOEVP
The system for high-accuracy determination of GLONASS ephemeris and time corrections (SVOEVP) is intended for provision of high-accuracy solutions of user navigation and time determination problems:
in real time
by refining SVOEVP adaptive parameters of S/C GLONASS motion model and measurements model, by calculating SVOEVP calibration corrections for user navigation equipment to compensate for errors errors due to frequency division of GLONASS navigation signals.

not in real time
by calculating high-accuracy ephemeris and time information, parameters of Earth rotation, ionosphere model parameters, wet component of troposphere, assisting data, etc.

4


SVOEVP composition
GLONASS navigation equipment calibration facility Information collection, processing, and control center

Metrological check station

Station for calculation of assisting information and provision of assisting technologies for GLONASS accredited users

SVOEVP

Own measurement stations (GMS and SLR)

Station for collection, analysis and preliminary processing of information from domestic civilian and foreign information sources and presentation of results to civilian organizations and individual users.

5


SVOEVP measurement information composition
SVOEVP is a multifunctional system for processing and analysis of diverse measurement information.

2011 1. Global network of GMS stations ­ up to 250 stations
2. 3. Network of international (30) and domestic (10) SLR stations Very Long Baseline Interferometry (VLBI) "Quasar-KVO" ­ 3 stations

By 2020 SVOEVP is planned to include 1. 2. 3. DORIS network stations ­ up to 50 stations. Water vapor radiometers (WVR) network in Russian territory ­ up to 15-18 stations. Expansion of networks: GMS ­ up to 400 stations, SLR ­ up to 50-60 stations (including more then 30 from ILRS network), VLBI ­ up to 4-5 stations. 6


SVOEVP tasks
SVOEVP is a part of GLONASS, an unique system having no world analogs because it implements most part of abilities of various international services such as IGS, ILRS, IERS, etc.
Quality improvement of navigation services · calculation of initial data for navigation frame accuracy factor, · refinement of adaptive parameters of motion and measurements model, · refinement of initial geodetic data of measurement stations

Solution of fundamental problems · support of Federal Geocentric Coordinate System, · calculation of geodynamic data

Provision of navigation in posterior mode · Posterior ETI GLONASS/GPS, · parameters of local models of ionosphere, troposphere, etc., · positioning in relative mode; · navigation of orbital users in absolute mode

SVOEVP

Real-time navigation · assisting technology, · user navigation equipment calibration

Information support (computer bulletin, general evaluations of GLONASS and GPS navigation field characteristics, information decisionmaking bulletins, etc.)

7



For GNSS users (SVOEVP web site http://www.glonass-svoevp.ru): 1. High-accuracy ETI GLONASS/GPS (Galileo, Compass ­ as soon as they are in operation) ­ SP3, RINEX, RINEX_CLOCK, SINEX, IONEX, ANTEX, ERP, TRO, etc. 2. Official information from the System Control Center (SCC) 3. Distribution of GGSK PZ-90.02 (stations catalogue) 4. Calibration delays for GLONASS navigation equipment 5. For accredited users - SBAS, RTCM SC-104, PMD, etc. Legal aspect: SVOEVP is the only legitimate source of distribution of bulletins about past and planned events with GLONASS S/C ("computer bulletin"), information bulletins about state of orbital constellation In addition: accuracy characteristics of navigation fields of GLONASS and GPS (Galileo, Compass ­ as soon as they are in operation), their 8 comparison results, recommendations.


Accuracy of solutions with use of SVOEVP data
Parameter name Equivalent error of pseudo range at the probability level P=0.95 due to errors of the space segment at any daily interval using posterior ETI Error, at the probability level P=0.95, of calculation of translation parameters between Federal Geocentric Coordinate System and coordinate systems of other navigation systems: parameters of relative reference to the Earth center of gravity parameters of mutual orientation Error (RMS) of determination of Earth rotation parameters: pole coordinates duration of day 0, 0004 a r c s 0, 07 ms 0. 02 m 0. 2 m < 10 min Value 0. 33 m

0. 05 m 0. 001 arc s

Error, at the probability level P=0.95, of determination of GMS coordinates Error, at the probability level P=0.95, of calculation of calibration corrections for GLONASS navigation equipment Delay in determination of worsening of GPS navigation field characteristics

9


Use of collocation nodes measurements in SVOEVP

SLR +

GMS +

VLBI

Calibration of user navigation equipment Methods of calculation of relative inter-frequency delays in GMS were developed and implemented in SVOEVP. Relative inter-frequency delays for the global network of stations are available at the SVOEVP web site http://www.glonass-svoevp.ru
10.5 10 9.5 9 8.5 8 7.5 7 6.5 6 5.5 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

World Time (UT1) Mutual coordination of mathematical models of measurements has been performed in SVOEVP. As a result, mutual processing of GMS and VLBI measurements with obtaining closedform series of Earth rotation parameters and GLONASS ephemeris was implemented at the competitive level.

10


SLR place in provision for current SVOEVP tasks

1. 2. 3.

[]

4. 5.

6. 7.

Check of distribution of the Federal Geocentric Coordinate System (FGCS) by GLONASS navigation signals. Calculation and check of translation parameters FGCS - ITRF. SVOEVP ephemeris verification using SLR measurements, verification of corrections of onboard time scale using combined one-way and two-way SLR and GMS range measurements. Refinement of initial geodetic data of GLONASS GCS stations (calculation of ground stations velocities) Refinement of location determination of phase centers of satellite antennae systems and analysis of spacecraft attitude system work quality. Support of malfunctioning GLONASS satellites in the case of partial and complete failure of onboard radio systems. Verification and refinement of models parameters used in SVOEVP (motion model, measurements model, geopotential model, etc.) 11


Perspective of development of laser ranging and SVOEVP Near-term outlook ­ development and implementation of models, methods and technology for implementation of one-way SLR in SVOEVP Accuracy of comparison of on-board and ground time ( ) . [ r Fi] st time in GLONASS history! One-way SLR creates prerequisites for building complete close-loop feedback system checking all navigation field errors due to space segment: errors of ephemeris and geodynamic parameters errors of time and frequency information; errors of FGCS scales ~ 0.1 ns

in SVOEVP a components of ;

12


Ways of refinement of SVOEVP characteristics

1. Creation of sub-millimeter accuracy one-way and two-way SLR and development of stations network. 2. Development od S/C "BLITS" with millimeter-level target error for refinement of the geocenter position determination and relative reference of measurement stations at the promising levels of accuracy 3. ]Commissioning of a one-way SLR, determination of S/C [ GLONASS time scale differences at picosecond level of accuracy. 4. Development of inter-satellite SLR. 5. Building of SVOEVP-based system for check of ephemeris and time and frequency corrections of GLONASS, geodynamic information, distribution and transfer of FGCS to end users.
13


Expected results ofimprovement of SVOEVP by year 2020
Parameter Positioning error in Federal Geocentric Coordinate System due to space segment: -in real time -in posterior mode Errors of Federal Geocentric Coordinate System: -reference between FGCS and the center of gravity of the Earth and rotation angles -distribution and transmission of FGCS Error in determination of Earth rotation parameters: - pole coordinates - duration of day Error of time scales: - GLONASS system time scale and UTC(SU) - UTC(SU) and UTC Error of determination of user time in GLONASS system time scale due to space segment errors 4 ns 3 ns 1 ns 0. 0001
arc s

Value

0. 10 m 0. 03 m

0. 01 m 0. 02 m

0 . 0 1 ms

14