Institute of Solid State Physics, Russian Academy of Sciences. Laboratory of Physical-Chemical Basis of Crystallization (LPCBC). Chernogolovka, Moscow district, 142432 Russia. Phone: +7-496-522-2074 Fax: +7-496-522-4691 E-mail: lpcbc82@issp.ac.ru Web Sites: www.issp.ac.ru/lpcbc www.sttic.com.ru |
R 23/25 Toxic by inhalation and if swallowed. |
Immediately remove any clothing soiled by the product. Remove breathing apparatus only after contaminated clothing has been completely removed. In case of irregular breathing or respiratory arrest provide artificial respiration. Supply fresh air. If required, provide artificial respiration. Keeppatient warm. Seek immediate medical advice. Wash with water and soap and rinse thoroughly. Rinse opened eye for several minutes under running water. Then consult a doctor. Do not induce vomiting; immediately call for medical help. Seek immediate medical advice. |
Product is not flammable. Use fire fighting measures that suit the surrounding fire. resulting gases: In case of fire, the following can be released: Toxic metal oxide fume Wear self-contained respirator. Wear fully protective impervious suit. |
Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation Do not allow material to be released to the environment without proper governmental permits. |
Keep container tightly sealed. Store in cool, dry place in tightly closed containers. Ensure good ventilation at the workplace. Open and handle container with care. The product is not flammable No special requirements. Do not store together with acids. Keep container tightly sealed. Store in cool, dry conditions in well sealed containers. Store under lock and key and with access restricted to technical experts or their assistants only. |
Properly operating chemical fume hood designed for hazardous chemicalsand having an average face velocity of at least 100 feet per minute. Components with limit values that require monitoring at the workplace: Cadmium and compounds, as Cd
The usual precautionary measures for handling chemicals should be followed. Keep away from foodstuffs, beverages and feed. Remove all soiled and contaminated clothing immediately. Wash hands before breaks and at the end of work. Store protective clothing separately. Use suitable respirator when high concentrations are present. |
|
Decomposition will not occur if used and stored according to specifications. Acids |
Cadmium compounds are highly toxic and experimental carcinogens. Exposure affects the respiratory tract, kidneys, and liver. Ingestion may cause nausea, salivation, vomiting and diarrhea. Ingestion or inhalation of cadmium compounds may be fatal. To the best of our knowledge the acute and chronic toxicity of this substance is not fully known. |
Do not allow material to be released to the environment without proper governmental permits. |
Cadmium compound, solid, cadmium tungstate |
20/21 When using do not eat, drink or smoke. 28 After contact with skin, wash with plenty of water 45 In case of accident or if you feel unwell, seek medical adviceimmediately. For use only by technically qualified individuals. |
Employers should use this information only as a supplement to other information gathered by them, and should make independent judgement of suitability of this information to ensure proper use and protect the health and safety of employees. This information is furnished without warranty, and any use of the product not in conformance with this Material Safety Data Sheet, or in combination with any other product or process, is the responsibility of the user. |