Yulia Sokolova et al.: Impact of Covariance Information on the Orientation Parameters Between Radio Source Position Catalogs, IVS 2012 General Meeting Proceedings, p.339­341 http://ivscc.gsfc.nasa.gov/publications/gm2012/sokolova.pdf

Impact of Covariance Information on the Orientation Parameters Between Radio Source Position Catalogs
Yulia Sokolova 1 , Zinovy Malkin
1) 2)

2

Pulkovo Observatory Pulkovo Observatory and St. Petersburg State University e-mail: julia.rs07@hotmail.com

Contact author: Yulia Sokolova,

Abstract
As was shown by Jacobs et al. (2010), accounting for correlations between the source positions derived from VLBI global solutions significantly changes the orientation parameters between compared CRF realizations if a microarcsecond level of accuracy is required. In this study we performed more detailed analysis of this effect. We conducted comparisons of a commonly used rotational alignment model of three parameters with three methods of accounting for the covariance information: using the position errors only, using only RA/DE correlations reported in radio source position catalogs in the IERS format, and using the full covariance matrices. CRF solutions from several IVS Analysis Centers providing the CRF solution in the SINEX format were used for this work. Detailed results of this analysis are reported.

1. Intro duction
Catalogues of radio source positions (RSC) derived from Very Long Baseline Interferometry (VLBI) observations have been used by the International Astronomical Union (IAU) to establish the International Celestial Reference Frame (ICRF) since 1998. IVS Analysis Centers provide these catalogs in a standard IERS format, where together with radio source positions and other relevant information, RA/DE correlations are reported. The IERS format includes, in fact, only diagonal covariances, and the off-diagonal correlations, except as mentioned, are not published. Meanwhile, some IVS Analysis Centers produce solutions in SINEX format where a full covariance matrix is presented. However, none of this information (not even only the diagonal covariance information) is used for the RSC alignments. Jacobs et al. (2010) investigated the influence of using a full correlation matrix on the rotation parameters. Their results showed that using a full correlation matrix for the radio source positions changes the orientation parameters significantly at the microarcsecond level of accuracy. In this work we present the results of comparison of the conventional model of mutual rotation between individual catalogs with respect to three alternative methods for implementation of the information about covariances: using the position errors only, using only the RA/DE correlation information which is reported in catalogs submitted in the IERS format, and using the full covariance matrix from the SINEX files.

2. Comparisons
CRF solutions in SINEX format from IGG, TU Vienna, and Institute of Applied Astronomy (IAA) IVS Analysis Centers together with CRF solutions in IERS format of the Paris Observatory (OPA), Federal Agency for Cartography and Geodesy (BKG), and the Space Geodesy Center (CGS) have been used in this work. Results are presented in Tables 1 and 2.
IVS 2012 General Meeting Proceedings 339


Yulia Sokolova et al.:

Impact of Covariance on Orientation

Legend for Tables 1 and 2: 1 ­ using the position errors only, 2 ­ using position errors and RA/DE correlations (IERS format), and 3 ­ using the full covariance matrices from SINEX files. SNX in the first column means a SINEX file has been used, and IERS means that a catalog in IERS format has been used. `WRMS before' and `WRMS after' mean WRMS differences before and after rotation by angles A1, A2, and A3. Units: `µas' for angles and `mas' for WRMS.
Table 1. Orientation parameters between ICRF2 (IERS format) and catalogs, only ICRF2 defining sources.

A1 IAA2009a (SNX) 1 2 3 1 2 1 2 3 1 2 1 2 1 2 36.790 ± 32.769 37.222 ± 32.864 37.222 ± 32.864 19.106 ± 3.859 19.222 ± 3.830 0.183 ± 8.627 1.104 ± 8.309 1.104 ± 8.309 -23.980 ± 4.083 -24.175 ± 3.964 -20.130 ± 26.046 -21.436 ± 26.001 4.523 ± 3.505 4.666 ± 3.444

A2 -6.506 ± 33.021 -7.580 ± 33.126 -7.579 ± 33.126 -22.992 ± 3.889 -23.224 ± 3.864 -31.813 ± 8.692 -32.150 ± 8.382 -32.148 ± 8.382 -11.868 ± 4.116 -12.425 ± 4.003 -13.012 ± 25.265 -13.001 ± 25.424 -10.007 ± 3.534 -10.401 ± 3.475

A3 9.627 ± 29.338 9.883 ± 29.374 9.883 ± 29.374 5.721 ± 3.417 5.743 ± 3.385 25.339 ± 7.696 25.810 ± 7.403 25.808 ± 7.403 13.140 ± 3.602 15.442 ± 3.495 8.241 ± 23.429 12.360 ± 23.405 8.136 ± 3.121 8.980 ± 3.063

WRMS b efore 0.4822 0.4839 0.4839 0.0583 0.0579 0.1261 0.1228 0.1228 0.0616 0.0600 0.0581 0.0582 0.5260 0.0520

WRMS after 0.4816 0.4832 0.4832 0.0552 0.0548 0.1234 0.1200 0.1200 0.0590 0.0570 0.0557 0.0557 0.0518 0.0512

IAA2009 (IERS) IGG2012 (SNX)

BKG2010 (IERS) CGS2010a (IERS) OPA2012a (IERS)

Table 2. Orientation parameters between IGG SINEX catalog and IAA SINEX catalog calculated using ICRF2 defining sources only.

A1 1 2 3 -17.474 ±3.414 -17.537 ±3.384 -31.416 ±16.172

A2 -11.787 ±3.662 -11.734 ±3.721 -8.301 ±17.817

A3 22.401 ±3.082 21.875 ±3.089 10.288 ±14.840

WRMS b efore 0.0544 0.0542 0.0487

WRMS after 0.0505 0.0504 0.0486

3. Conclusion
Our analysis revealed significant differences between rotation parameters computed without accounting for correlation information, with using the full covariance matrix, and with RA/DE
340 IVS 2012 General Meeting Proceedings


Yulia Sokolova et al.:

Impact of Covariance on Orientation

correlations, which confirms the results of Jacobs et al. (2010). Unfortunately, we could only work with one modern catalog in SINEX format from IGG, so the results should be treated as preliminary.

Acknowledgements
The authors appreciate the IGG team, TU Vienna, especially Hana Kr´ a, for the great efforts asn´ they made to provide a CRF SINEX solution for our work.

References
[1] Jacobs, C., et al., Rotational Alignment Altered by Source Position Correlations, IVS 2010 General Meeting Proceedings, NASA/CP-2010-215864, D. Behrend and K. D. Baver (eds.), p. 305­309, 2010. [2] Ma, C., et. al., The Second Realization of the International Celestial Reference Frame by Very Long Baseline Interferometry, IERS, Technical Note No. 35, 2009.

IVS 2012 General Meeting Proceedings