MopraNotes

At the start of each check experiment

  • CAIN - integration time
  • Focus
  • Attenuation
  • Hybrid
  • Coherence

N.B. For hybrid setups and checking coherence see the separate notes at Mopra setup notes. Some of the software setup described below may also be needed for this hardware testing.

If starting up from scratch, follow these notes.

The following software needs to be run for setup and running an experiment:

Integration time

The integration time already setup is shown in the camon window (use /mopra-x in camon to see all bands). If it needs to be reset use:

 > newcain cycle <sec>  - to setup the integration cycle time in secs.

Default cycle time has been 10s but mm observers often use ~2sec. For VLBI 5sec may be more appropriate. To see what else "newcain" can do just type "newcain" without any parameters and it will give you a list of commands. CAUTION: Please only use "newcain" if you really understand what you are changing.

attest

attest can be used to set attenuation, focus the receiver and stow the antenna. Run attest by logging into bigrock as observer and running

 > attest &

Attenuation

Generally automatic attenuation in vlobs should be turned off. It often gets the wrong value and SDO measurements saturate, giving no Tsys values. Select the "atten" tab in attest.

Coarse attenuators should be set to "0 0 0 0" for L and S band and "1 1 1 1" for everything else. To adjust the fine attenuators, check the current settings show in camon (attest does not display the current settings) and choose the appropriate values. Then click "go". If the attenuators are set to an appropriate value, the DAS IF selev and offset should be roughly midrange, GTP should be ~1.0-4.0 and SDO should > 0.0 and < 4.9, if the Tsys value seen by vlobs are not be zero.

For the 22 GHz receiver with the quarter-wave plate for circular polarisation the setup has mm-attenuators at " 7 4" (check in Monica that the C26 levels are below 15 V), the coarse attenuators are set at "2 2 2 2" and the fine attenuators are adjusted for the right GTP and SDO levels as described above (Aug'08 that was "4 1 2 2").

Focus

Each frequency has a separate focus setting. To set this, choose the "focus" tab in attest and move the slide to the correct value and click "Go".

Antenna stow

To stow the antenna exit vlobs and choose the "stow" tab in attest. Then click the "go" button.

Antenna control

Mopra is run by the program vlobs. This points the antenna, sets up the frequency and logs Tsys.

TCS should not be run at the same time as vlobs. Before starting vlobs for the first time, run

 > killtcs

Schedules

Copy the sched input file from the atnf ftp area for this experiment, e.g. v001a_Mp.com. This needs to be converted into a vlobs file. Normally these should be copied onto bigrock at ~atcaobs/sched_vlbi. atcasched is used to do the conversion. E.g.

 > atcasched
 > @v001a_Mp.com
 > write
 > exit

vlobs

To run vlobs log into bigrock as observer and run "vlobs". There is a startup bug, it can take dozens of times before it actually starts. If your terminal is full of garbage characters, use the "reset" function of the terminal (middle mouse button on an xterm, or a menu option on fancy terms (e.g. Unsed "terminal" on gnome-terms.

The main vlobs commands are:

fileLoad the selection schedule, e.g. file v001a
startStart the schedule running
stopStop the currently running schedule
set att servo offTurn off attenuation servo loop
lo_disableDisable setting of frequency chain
lo_enableEnable setting of frequency chain
stowStow the antenna, but better to quit vlobs and use attest

Recording

Usually Mopra data is recorded remotely to Narrabri, onto cavsi2.

Run cdisko as normal but make the following changes:

  • Select Remote Disk Recording in the recording mode selection
  • Select the Configure->Show eVLBI settings menu item to get the eVLBI dialog
  • Set the following values
Remote Hostnamecavsi2-ext2
TCP Port #9999
TCP Window size400

Record as normal

Post observing

At the end of the session (or during as well if required) you need to copy the mopra logs down to Sydney. Log onto any machine in Epping as "vlbi" and run the command mopralog.sh

 > mopralog.sh

This will invoke rsync to copy down the logs directory.