Документ взят из кэша поисковой машины. Адрес
оригинального документа
: http://www.atnf.csiro.au/vlbi/dokuwiki/doku.php/correlator/records/v255c
Дата изменения: Unknown Дата индексирования: Mon Apr 11 21:38:07 2016 Кодировка: IBM-866 Поисковые слова: cygnus loop |
Stations: ATCA, Mopra, Hobart, Ceduna, Parkes
ATCA reference station is W104 (CA04).
RPFitsChannelExtractor <inputfilename> <outputfilename> 2048 11264
)Note: A priori Tsys (SEFD) is different for ATCA for the dual-pol (higher freq) than for the 4 IF, single pol mode. I have not changed the default factors this time (v255b used nominal SEFD=70 Jy for all). The nominal SEFD applied for ATCA is listed for each file below.
Problems: On loading Mopra disk set at Curtin, file system not recognised. fsck
determined an ext3 file system with journalling badly corrupted/lost. Only 5 minutes of Mopra data from v255c (UT range 2246-2251) were recovered.
Output files:
File name | Description | DOY/UT range | Polarizations | # subbands (AIPS IFs) | Bandwidth per IF (MHz) | Spectral channels per IF/pol | Corr. int. time (s) | ATCA Nominal SEFD |
---|---|---|---|---|---|---|---|---|
v255c_icrf_2222-2337.rpf | ICRF run at start | 330/22:22:00-22:37:10 | LL | 4 | 16 | 256 | 2 | 70 |
v255c_icrf_0802-0900.rpf | ICRF run at end | 331/08:02:00-09:00:00 | LL | 4 | 16 | 256 | 2 | 70 |
v255c_cont.rpf | Continuum pass for dual pol setup, all sources correlated (incl. maser targets) | 330/23:37:10-331/08:02:00 | RR, LL | 2 (IF #3 and #4) | 16 | 256 | 2 | 170 |
v255c_NGC6334IN.rpf | 1st maser target, 6667-6669 MHz range | 330/23:37:10-331/08:02:00 | RR, LL | 1 (IF #4) | 2 | 2048 | 2 | 170 |
v255c_NGC6334F.rpf | 2nd maser target, 6667-6669 MHz | 330/23:37:10-331/08:02:00 | RR, LL | 1 (IF #4) | 2 | 2048 | 2 | 170 |
v255c_cal_fullres.rpf | 5 mins on calibrators 1741-038 and 1749+036, 6667-6669 MHz | 331/03:43:30-03:48:30 | RR, LL | 1 (IF #4) | 2 | 2048 | 2 | 170 |
File-1:
Comments: Spikes in the ATCA bandpass?
Plots of uncalibrated amplitude and phase against frequency
Comments: Ok
Plots of uncalibrated amplitude and phase against time
Comments: Ok
Comments: Ok
Comments: Ok
Comments: Ok
Plots of Amplitude and phase against frequency with fringe-fitted solutions applied
Comments: Looks Ok
Plots of Amplitude and phase against time with fringe-fitted solutions applied
Comments: Looks Ok
File-2:
Comments: Spikes in the ATCA bandpass?
Plots of uncalibrated amplitude and phase against frequency
Comments: Ok
Plots of uncalibrated amplitude and phase against time
Comments: Ok
File-3:
Comments: Spikes in the ATCA bandpass?
Plots of uncalibrated amplitude and phase against frequency
Comments: Ok
Plots of uncalibrated amplitude and phase against time
Comments: Ok
Comments: Ok
Comments: Ok
Comments: Ok
Plots of Amplitude and phase against frequency with fringe-fitted solutions applied
Comments: Looks Ok
Plots of Amplitude and phase against time with fringe-fitted solutions applied
Comments: Looks Ok