Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.atnf.csiro.au/research/pulsar/new/index.php?n=Pdfb4.Search
Дата изменения: Unknown
Дата индексирования: Tue Apr 12 20:30:15 2016
Кодировка:

Поисковые слова: п п п п п п п п п п п п п
Pulsar group | Pdfb4 / Search

Group

Projects

Observing

Processing

  1. Tempo2 wiki
  2. Updating clock files
  3. Updating ut1.dat

Data Archive

Multimedia

External Links


edit SideBar

Search

PDFB4 search mode

The following tests were carried out on the 4th May 2010 by George Hobbs. For each configuration the minimum sampling rate was determined by observing 0437-4715 for 60seconds with the specified setup. Note: the sample times were analysed in powers of two. Therefore if 64us is reported as the fastest sample time then 32us failed. However, it is possible that some sample time between 32 and 64us may actually work. The fastest sample time must also be treated with caution. For instance, the 1024_512 configuration worked twice with 8bits, 1pol and 64us sampling, but then failed on a third test. The fastest sample time for this setup has therefore been reported as 128us.

Results

Configuration: 1024_512 (bandwidth = 1024MHz, number of channels = 512) samples/row = 4096, cycle time = 10s, 10cm receiver, PDFB4.
Configuration: 256_1024 and 256_512: 1420.406MHz, number of channels = 1024/512 (respecitvely), samples/row = 4096, cycle time = 10s, MB receiver, PDFB4.

nbitsnpol1024_512 (us)256_1024 (us)256_512 (us)
116412864
2164128128
4164128128
81128128128
12128256128
22128256128
42128256256
82128256256
14256512256
24256512256
44256512256
84256512256
Page last modified on May 04, 2010, at 08:37 PM