Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.atnf.csiro.au/research/pulsar/timing/newclkcorr.html
Дата изменения: Unknown
Дата индексирования: Sun Dec 23 04:21:42 2007
Кодировка:

Поисковые слова: 3
Clock Corrections at Parkes

Clock Corrections at Parkes

The GPS and GPS Common-view are the methods used to refer measurements made using the Parkes observatory clock ("UTC(PKS)") to Universal Coordinated Time (UTC). The offset between the Mark IV Parkes clock and the time standard of the Global Positioning System (GPS) is measured by the Totally Accurate Clock 2 system. Transfer from GPS time to UTC is done by applying offsets reported by the Paris observatory of le Bureau International des Poids et Mesures (BIPM) in Circular T. The offset between the Parkes Mark IV clock and the National Time Scale, UTC(AUS), which is Australia's realisation of UTC, is derived from the caesium clocks at the National Measurement Institute (NMI). The clock tie is performed using a common-view GPS service provided by the NMI. Transfer from UTC(AUS) to UTC is possible via the offsets reported in Circular T. These methods of the clock corrections commenced on the MDJ 50844. Previously used scheme of linking Parkes clock to the UTC is described here.

Currently used scheme is fully integrated into tempo2, where fairly regularly sampled values of the offset between pairs of clocks are recorded in ASCII text files, one pair per file. The files begin with a sequence of one or more comment lines beginning with '#', the first of which specifies the name of the clock to convert from, followed by the name of the clock to convert to (e.g. UTC(PKS) UTC(GPS) means the file contains UTC(GPS)−UTC(PKS)). The remainder of the file comprises one line per sample, each consisting of the MJD and the offset in seconds, separated by whitespace. Given a measurement made with one clock, a sequence of file names and a desired clock to which to refer the measurement, corrections can be made by adding the terms with the appropriate signs (see the tempo2 manual for operational details). The simple file format facilitates visualisation by generic plotting utilities, and basic manipulation with standard unix tools. Custom utilities include update_clkcorr, which imports and pre-processes data from external sources, and compare_clkcorr, which constructs difference values for an arbitrary collection of clock pairs, interpolated to a common set of equally spaced MJD samples, and outputs the result in ASCII format for plotting or further processing.

Procedure to update the clock corrections

The primary repository of clock correction data is the tempo2 clock directory: $TEMPO2/clock.
Before doing anything else, do a CVS update in $TEMPO, $TEMPO2, and $CVSHOME/soft_atnf/atas/clkcorr.

If you are using tempo instead of tempo2, you will have to update $TEMPO/clock/time.dat. To do this, go to $TEMPO/clock/ directory and run the backward-compatability program:

make_time_dat -m MJD >> time.dat,

where MJD is the Modified Julian Day after the final entry in time.dat. You will also need to update $TEMPO/clock/utccorr.tot using the following command (or similar):

awk '{if ($1 > 53184) printf " %8.2f %18.1f\n", $1, $2*1e9}' < $TEMPO2/clock/nist2utc.clk >> utccorr.tot .
Both files contain a dummy entry for MJD 60000, which you will need to move to the bottom of the file with a text editor. Double-check both files for continuity over the transition from old to new data, then commit them to CVS.

To update the common-view clock correction scheme (see above), the following files are necessary instead of pks2gps.clk and gps2utc.clk:


Last update: 2007 February 06 — Lucyna Chudczer