Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.atnf.csiro.au/pub/people/vlbi/corrsched/expt.99%3B40
Дата изменения: Mon Jul 28 05:29:10 2003
Дата индексирования: Mon Dec 24 23:51:33 2007
Кодировка:

Поисковые слова: storm

v041r 1999/031 Tid(JLauf) Hob(MEC/Dai?)
=====
Fringes found first go at 2040!

Tid:
152112 start: site power failure before start: lost 4h06m.
130nS delay difference between s and X !


V100f2 1999/072
======
Hob:
073/0016 TR #4 stopped, AT-3-000390/1e. Used 'transport 4 record'.


v128a 1999/073 Pks(JER,TLG) Narr(AKT/HEB/Hosokawa-san) Mop(RO)
===== Mop(MEC,DJL...) Ceduna(DM,RD), Tid(JEJL,DLJ,JLauf)

AT:
CA02 on Stn 21 throughout session
0749-0752 whopping RFI
0800-0802 more RFI

0823-500: 5.65Jy (2260)
0537-441: 2.62Jy
0407-658: 8.60Jy
0405-385: 2.10Jy (2260,2284)
2152-699 - CA01 LO correction is bad during the day:

HOB:
Pointing was stuffed for this whole session (by tests that left
Ceduna's pointing parameters in the system). Can see fringes on
most sources, but despite efforts of Richard D, data are essentially
uncalibratable.

V093f1 107/0600-2310 Pks(JER) AT(AKT,RHF) Tid(DLJ,JEJL) Hob(SJE?)
======

Tid:
Power failure earlier in the day, K-band stuck in ambient load:
had to reconfigure from cone. On source ~0820UT?
0537-441 boresights ~1.5md both axes
0820UT on source
0845UT 1144-379 0Ax, 1.5El

Pks:
H-maser playing up in the days before the run.
~1 turn of phase from temperature cycling in focus cabin.
Ran with 10kHz tone at bottom of band 1 to monitor phase.
1408: coherence went bad right before my military eyes:
checked H-maser: looked OK
1500-1546 off src to check: removed some bubble-wrap from Wiltrons,
1546-1610 coherence returned on 1921-293 scan
1610-1643 bad (non existent in fact) coherence on Circinus
1643-1725 more tests: removed all bubble-wrap, raised top Wiltron
clear to give 2~3" gap. No joy.
1735 breakthrough: checking 10MHz drive levels into Wiltrons
in control room, found bad BNC on sohrt patch into #31.
All OK now, except unlagged Wiltrons executing ~7 turns
of phase on every thermal cycle!


V093f2 108/0600-2030
======
TID:
0600 F1: no bandpass slope, but very lumpy and birdie-ridden.
0600 F2: ~1:4 bandpass slope, many birdies.

Pks:
Re-packed focus-cabin Wiltrons in bubble-wrap, upped A/C to ~26C and
left lift-leg door ajar.
0912, 1028, 1345 UT: focus-cabin A/C still kicking-in, with 3~4 turns
of phase each time (at 1345 anyhow)
1440: opened hatch and lift door in cabin; now stable at around 25C.

172930-173000 switched briefly to RCP

1600: high perrs on ATNF0281.5 : swapped to at06/6 OK

CAT:
0600: large "midband birdie" on alternate 5s cycles (00-05s), both F1,F2.

This is presumably the blanking pulse - didn't see this
when recorrelated A/Cs in June 2002 (with cycle 10 .0625 .02).
-JER 26-Jun-2002

V129A 1999/162 (AKT Mopra=> AT)
=====
ATCA: ~1020 off src?

Mop: pols reversed (LCP/RCP)
0940: pol purity on 1934-638: RR=LL=11.0, RL=0.7, LR=.55

N4945 shows complex structure, flux peaking at ~110mJy.
No obvious sign of lines.

V034A2 1999/168
====== Fringe-search for V034, and ????

CaT - ants 12345_ arrayed for V034 part, instead of single antenna.

Nothing found on V034a2 sources in first correlating pass

Fringe-search
J0624-5417 weak detection on AT-Mop only,
SNR~16 in 16MHz BW in ~200sec.
J0625-5438 good detection all baselines,
SNR 82~120
Flux ~ 0.3Jy on all baselines
J0626-5432 J0625-54 in the beam with wide search window,
weak (SN 4~5) detection on AT-Hob off centre,
at position 06:26:49.55, -54:32:34 (close to Tasker position)
J0648-5657 Weak detection: SNR 5~7 all baselines
=> 06 48 01.05 -56 57 29.4
J0704-5514 Detected SNR ~7.5 all baselines, at source position:
=> 07 04 12.63 -55 14 40.7 (cf Tasker PMN list)

V135A
===== Correlated SNRs
ATCA fluxes at 8425MHz CA-PK HO-PK CD-PK CA-HO CA-CD
J0431-6406 0.18Jy 79-66 28-17 13-10 29-22 13-22
J0509-6853 ~30mJy undetected ( <4 all baselines)
J0515-6721 0.36Jy 90-100 3-12 8-3 3-10 3-9
J0516-6207 0.60Jy (0516-621) 300-600 85-120 58-82 145-155 76-127
J0516-7149 0.15Jy 36-24 6-10 3-5 9-13 5-6
J0516-7237 0.38Jy 205-227 60-65 43-47 67-74 48-57
J0529-7245 0.43Jy (0530-727) 241-323 51-68 39-99 80-99 57-69
others < 30mJy (on closer inspection, Tasker's list shows many of
these to be extended).
0407-658: 0.97Jy 113-356 8-14 6-11 14-23 6-15
0637-752: 6.0Jy
0537-441: 5.7Jy
1104-405: 2.35Jy
1424-418: 3.05Jy
Cen-A: : ~6Jy


v128b1 1999/165
=====

Pks: 15:11:48 Cen-A sets


v100g 1999/259 Pks(JER,DLJ,JMS) AT(HEB,AKT) Mop(RO,AKT) Tid(JEJL,JL) Hob(??)
=====

Bad storm at start of run, Parkes, Mopra wind-stowed.

Pks:
1208 finally underway after storm (wind-stowed for 6 hours)
1506 S2 started from console (label command mis-typed)
174140 label command entered correctly, tapes stop/start
0100 - 0137 off src (operator distracted)

Mop:
151420 : late tape start
183125 : transport 5 cut out
203640 : transport 5 restarted (JER)
0102 - 0146 antenna drive off

ATCA:
~1116 begin cal on 1934-638, after ToO observation
1029 - 1048 1934-638 again
1048 - 1113 on source 1519-273
1113 - 1127 1934-638 cal
1149 continuous CACAL re-started, ANT=12345_
1152 1519-273 sets
125200 - 132700 no data: switch to ToO observation
1508 ANT=___45_ (lousy phases)
1515 Stopped continuous CACAL
1535 - 1539 off source: ACC died
1602 restarted continuous CACAL
1603 ANT=12345_

4.8GHz 8.425GHz
1519-273 1.9 1.9 (.07, .1 pol)
1921-293 11 12
2005-489
0208-512 2.60 2.70 Jy
0537-441 5.36 5.88 Jy
1144-379 2.65 3.25 Jy
2.85 3.64 Jy at 0710UT
0537-441 5.42 5.94 Jy

v088m1
======

Mopra
Tape AT-3-00315/1b-1 (tr #1 of 1st tapeset) "almost blank"
(viz. occasional glimpses of timecode, otherwise blank, tape
claims to be in "sp" mode).

v135b1 352/1999 Pks(JER,DLJ,RHF) AT(AKT,HEB,SJT), Mop(RO), Hob(?), Ced(SJE)
======
Correlator: No finges on Ceduna baslines on v135b1_0800_1.rpf
playbacl not synched?
V034b1
======

AT: troubles continue with S2 UIC & delay jump errors: auto delay resetting
in bursts of 5~15 mins every hour or two.
353/0030 reboot S2 with refclkfix turned off.

Ref is CA04 on station 28, __345_ arrayed, phases spreading out
over ~100 degs at times.

353/0013-0022 CA06 stopped tracking

0340 1549-790 = 3.05Jy, phase spread ~100 degs on ants 345


Mop:
352/225701-353/004330: dish disabled itself: restarted
remotely by AKT (RO not answering).

v135b2
======

AT:
1240 5.6Jy for 0537-441 (6662MHz)