Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.atnf.csiro.au/computing/software/askapsoft/sdp/docs/current/calim/data_selection.html
Дата изменения: Unknown
Дата индексирования: Tue Apr 12 13:03:27 2016
Кодировка: ISO8859-5

Поисковые слова: scientist
Data Selection — CentralProcessor 0.11 documentation

Data SelectionТЖ

Data accessor layer provides a capability to pre-select the data based on some criteria. As all synthesis applications see only data returned by the accessor, it can be used to restrict Cimager (see cimager) and Ccalibrator (see ccalibrator) to use a given subset of the data. All synthesis applications understand the keywords given in the following table (must have Ccalibrator. or Cimager. prefix), i.e. Cimager.MinUV = 100). All these parameters are optional. If present, a corresponding data selection is done and only those data will appear in the iteration using accessor layer.

Parameter Type Default Description
Feed uint32 None Select a subset of the data corresponding to a particular feed (should be called synthetic beam in the ASKAP terminology). If defined, only data corresponding to the given beam will be read from the dataset and processed by either Cimager or Ccalibrator. The value is 0-based number of the beam.
Baseline vector<uint32> None Select a subset of the data corresponding to a particular baseline. If defined, only data from the given baseline will be read from the dataset and processed by either Cimager or Ccalibrator. The vector should have exactly two elements, which are treated as zero-based antenna indices.
Channels vector<uint32> None Select a subset of spectral channels. If defined, only a slice of the visibility cube is passed to either Cimager or Ccalibrator. Currently should always be a 2-element vector with the number of channels requested and the first channel (0-based) of the slice. The optional 3rd element of the vector is intended for on-the-fly averaging in spectral channels (it is a number of adjacent spectral channels to average). It is not yet implemented by the accessor, although understood at the parset level.
SpectralWindow uint32 None Select data from a given spectral window only. If defined, only data corresponding to this spectral window will be read. The value is 0-based index of the spectral window
Polarisations string None Intended for accessor-based selection of polarisation. Not yet implemented.
TimeRange vector<double> None Select a subset of data based on time. If defined, only data within the given timerange are read. Time is defined in UTC seconds since MJD 0.
CorrelationType string None Select certain type of correlations. Allowed values are: auto, cross and all. Defining this parameter allows to select, e.g. just cross-correlations.
ScanNumber uint32 None Select a single scan number. If defined, only data corresponding to the given scan number will be read from the dataset. The value is 0-based.
MinUV double None Select data based on the uv-distance (in metres). Only visibility points corresponding to uv-distance greater than the given value (defined in metres) are read from the measurement set. Note, the selection is done without taking frequency information into account.
MaxUV double None Select data based on the uv-distance (in metres). Only visibility points corresponding to uv-distance smaller than the given value (defined in metres) are read from the measurement set. Note, the selection is done without taking frequency information into account.

Previous topic

Solvers

Next topic

Access to calibrator solutions

This Page