Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.atnf.csiro.au/computing/software/askapsoft/sdp/docs/current/calim/calibration_solutions.html
Дата изменения: Unknown
Дата индексирования: Tue Apr 12 13:03:48 2016
Кодировка: ISO8859-5

Поисковые слова: ceres
Access to calibrator solutions — CentralProcessor 0.11 documentation

Access to calibrator solutionsТЖ

The code abstracts the way it accesses the calibration solution. It allows various ways of storing them (e.g. parset file, casa table, external database) via a factory class. This page contains documentation how to set up the factory. The parameters are shared by all synthesis programs and should be prefixed with the actual program name in the usual form, i.e. Cimager.xxx

Parameter Type Default Description
calibaccess string “parset” The type of calibration solution source. Only “parset” and “table” are currently implemented
calibaccess.parset string “result.dat” Parset file name where the calibration solution is stored. This parameter is meaningful only if calibaccess=”parset”. The keywords in this parset file are given in the form gain.g11.0.0 = [0.918308,0.000000], where g11 is for the first parallel-hand polarisation and g22 is for the second. The last numbers are the 0-based antenna and beam numbers, and the value is a complex value with real and imaginary parts given as a vector. Leakage parameters are given in the form leakage.g12.x.y and leakage.g21.x.y, respectively.
calibaccess.table string “calibdata.tab” The name of the casa table to be read or created.
calibaccess.table.reuse bool false Unless this flag is true, an old table or file, which name is given by calibaccess.table is removed if writing of the calibration solution is requested
calibaccess.table.maxant uint 36 Maximum number of antennas allowed (this parameter is required only if writing of the new calibration solutions is requested)
calibaccess.table.maxbeam uint 30 Maximum number of beams allowed (this parameter is required only if writing of the new calibration solutions is requested)
calibaccess.table.maxchan uint 16416 Maximum number of spectral channels allowed (this parameter is required only if writing of the new calibration solutions is requested)