The ADC card traditionally used with FIRPO I at CA has been used also for FIRP OII in Russia. For this, it has been necessary to modify the IRQ number, and as a result some confusion has been generated. In general, remember that at CA the IRQ=4 is used with both the old and the new versions of LUNOC (if a version has a different number as a default, it can be still modified via software in the ADC menu at the start of the programme). For this, the W16 jumper must connect B-and-H. At the PC in Russia, this IRQ is not available and we used IRQ=5: for this, connect W16 across C and I (just one step to the right from the CA configuration). For more details, see also the file ADC.TXT in the LUNA/DOC directory on the TM-5000. At the same time, the new PCMCIA ADC card (DASCard 1000) has been succesfully installed on the TM-5000 notebook, and used for instance to record the Alpha Tau occultation at Arcetri on March 14, 1997. Details on how to install and use the card are available on the notebook itself (check the local WEB homepage). In general, insert the card before turning on the PC: it will be recognized automatically at switch on. The card can be used with its commercial control program (it includes an internal clock), although L. Fabbroni is developing some specific software for LO purposes.
Note that S. Richter has had problems with the filter/clock box during his March 1997 run at CA. VC and I also observed some problems during the February run in Russia. Apparently, the clock does not always work properly: the problem, according to SRi, is some loose contact in one corner of the board inside. If you meet this problem, try to touch and shift and shake the box till it works, then leave it alone. In the near future, we have planned to replace the filter/clock box altogether, so this information may be soon superseded.
Andrea
From Steffen, 18 March 1997:
Der Stecker W16 auf der ADC-Karte (gleich oberhalb der Einsteckleiste in den Computer) muss am Calar Alto an der Position 'H' stecken. Beim PC in Russland ist es dann die Position 'I'. In der Filter/Clock Box war durch den Transport die Leiterplatte abgegangen und hatte einige Kontakte abgerissen. Ich habe wieder alles angeschraubt und angeloetet. Nur hat die Leiterplatte anscheined auch etwas abbekommen. Es gibt noch einen Wackelkontakt den ich nicht gefunden habe, wodurch das Clock-Signal (Rechteckimpuls an CK1 und CK2) ausfallen kann. Sollte nach einem Transport kein Rechteckimpuls sondern eine Gleichspanung am Clock-Ausgang anliegen, so hilft es meistens leicht an das Gehaeuse zu klopfen. Sollte das keinen Erfolg bringen, muss der Einschub aus dem Gehaeuse herrausgezogen werden (durch 2 Schrauben auf der Unterseite des Gehaeuses fixiert). Dann hat ein leichter Druck auf die rechte Seite der Leiterplatte bei mir immer geholfen. Da es mich gestoert hat, dass bei geringen Hoehen immer etwas Stickstoff aus dem Dewer auslief, habe ich 2 kurze Plastikschlaeuche auf die einfuellstutzen gesteckt. Damit kann man dann alle Stellungen des Teleskops anfahren, ohne dass der Stickstoff auslaeuft.