Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.apo.nmsu.edu/Telescopes/SDSS/eng.papers/19970527_PointErrorBudget/19970527.html
Дата изменения: Tue May 19 05:28:47 1998
Дата индексирования: Sun Apr 10 08:31:42 2016
Кодировка:

Поисковые слова: п п п п п п п п п п п п п п п п п п п п п п
Pointing error budget

2.5-m Telescope Pointing Error Budget

Sloan Digital Sky Survey Telescope Technical Note 19970527

Walter Siegmund


Contents

Introduction

The Sloan Digital Sky Survey imaging survey consists of 90 strips that are produced by scanning a great circle with the telescope. Each pair of strips make a filled stripe 2.5° wide. Thus, it is correct to say that the imaging survey consists of 45 stripes. The data are saved as 2048 x 1362 pixel frames

The interleaved strips and adjacent stripes overlap about 1 arc minute. It is desirable that large extended objects, i.e., nearby galaxies, be contained wholly within one strip or its neighbor. This will not always be possible, especially for galaxies with large angular diameters. However, a 2-D pointing accuracy of 3 arc seconds RMS leads to acceptibly uniform overlap and minimises the number of cases that require special handling (Table 3).

The requirement of efficiency in acquiring the guide stars in the setup for spectroscopy runs leads to the same number (Table 1). A guide fiber bundle diameter of 16.5 arc seconds and a pointing accuracy of 3 arc sec RMS results in 99% initial success in acquiring guide stars. This assumes that additional errors due to rotator angle, plate scale, star position, etc., are negligible.

Table 1: Pointing accuracy criterion needed for efficient spectroscopic operation.

Component

Value

Unit

Notes

Guide fiber bundle diameter

1

mm

1

Guide fiber bundle diameter

16501

mas

2

Image diameter

1000

mas

3

Max radius for acquisition

7751

mas

4

Number of standard deviations

2.58

5

Pointing accuracy (RMS)

3004

mas

6

Notes:

  1. One of the ten guide bundles will be 1.0 mm in diameter. The balance will be 0.5 mm in diameter.
  2. The telescope scale is 60.6 microns/arc second.
  3. We assume that the guiding algorithm will converge if the image center is 500 mas or more from the edge of the fiber bundle.
  4. See previous note.
  5. This corresponds to a 99% success rate for a Gaussian distribution.
  6. See previous note.

Pointing error budget

Table 2: Pointing error budget.

Component

2-D error

(mas RMS)

Notes

Tracking error (300 > f > 1 mHz)

100

1

Magnetic fiducial error

1500

2

Encoder error between fiducials (f < 1 mHz)

1000

3

Pointing model error

1000

4

Flexure (not in model)

1000

5

Mechanical Hysteresis

1000

6

Thermal deformation

1000

7

Refraction error (z = 45 deg)

400

8

Primary nonrepeatability

800

9

Secondary nonrepeatability

20

10

Camera nonrepeatability

200

11

Coordinate transformation error

10

12

Total

2846

13

 

Notes:

  1. This number is for the tracking error budget (Sloan Digital Sky Survey Telescope Technical Note 19970523). It is applicable over the listed frequency range. The unit mHz is millihertz.
  2. Assumes a specification for the magnetic fiducials of +/-15 microns worst case over the temperature range -20 to +20 deg C.
  3. Over several days, on the 3.5-m the locations of the fiducials repeat to 8 arc sec P-V. This includes magnetic fiducial error and encoder error.
  4. This only includes errors in determining model coefficients. The values of this and the three following items are set to a level that should allow rapid debugging of these effects. The major limitation, position noise from seeing should be below 100 mas RMS and should not contribute significantly.
  5. This includes all mechanical flexure that is not in the telescope model.
  6. This includes all mechanical hysteresis.
  7. This includes all errors due to temperature gradients in telescope components.
  8. The total refraction at this zenith angle is 60 arc sec. This varies by perhaps +/-1 arc sec during clear weather. The assumption here is that all but 100 mas RMS can be compensated using surface pressure, humidity and temperature measurements.
  9. Assumes use of linear stepper motors with an error of 0.6 microns RMS and that quantization error dominates.
  10. Assumes measured performance of the 3.5-m secondary.
  11. The kinematic mount for the 3.5-m optics test interferometer repeated to 1 micron. The camera is more massive and the mount more complex so a more conservative number is suggested. Gunn believes that 1 micron can be achieved.
  12. From Russell Owen.
  13. Statistical independence assumed.

    Table 3: Overlap error of adjacent or interleaved strips.

    Component

    2-D error

    (mas RMS)

    Notes

    1-d error

    2012

    1

    Strip overlap error

    2845

    2

    Peak-valley overlap variation (6 sigma)

    17070

    3

Notes:

  1. Only the error normal to the strip direction affects strip overlap.
  2. The error from two pointings determines strip overlap.
  3. Only 1 in 1000 overlaps will be worse than this. Each of the 90 strips will likely be observed in several segments. Consequently, several hundred pointing operations will be required.

Discussion

I believe this to be a conservative error budget that should be straightforward to satisfy initially. Also, it should be reasonable to maintain telescope pointing at this level. Should this prove impractical for some unforeseen reason, alternatives exist.


Date created: 05/27/97
Last modified: 05/28/97
Walter A. Siegmund
siegmund@astro.washington.edu