Octopus Cable for Xyplex MX1620 Terminal Server

Octopus Cable for Xyplex MX1620 Terminal Server

Each octopus cable connects 8 xyplex MX1620 terminal server ports to to a patch panel or 8-port harmonica with 6-wire 6-position RJ11 jacks. The patch panel or harmonica must be USOC-wired and have a male Telco connector, since this cable has a female Telco connector. This same wiring presumably works for all other xyplex terminal servers with RJ45 jacks.

If you wish to use hardware flow control then configure the xyplex for CTS/RTS handshaking.

Specifications

Each octopus consists of:

Each leg is four feet (4') long unless otherwise specified. The wiring is as follows. Use of twisted pair wire is optional, but if it is used, it must be used as shown in the table.

RJ45
Pin

Female Telco Connector Pin

Leg #1

Leg #2

Leg #3

Leg #4

Leg #5

Leg #6

Leg #7

Leg #8

twisted
pair

3

27

30

33

36

39

42

45

48

4

1

4

7

10

13

16

19

22

twisted
pair

5

26

29

32

35

38

41

44

47

6

2

5

8

11

14

17

20

23

twisted
pair

8

28

31

34

37

40

43

46

49

1

3

6

9

12

15

18

21

24

RJ-45 pins 2 and 7 must not be connected to anything. Telco pins 25 and 50 are also not connected.

Derivation

The octopus wiring is derived from the table below, as follows:

RJ45
Pin

RJ11
Pin

Signal

Telco Connector Pin

Leg #1

Leg #2

Leg #3

twisted
pair

3

2

Tx

27

30

...

4

3

Tx Gnd

1

4

...

twisted
pair

5

4

Rx Gnd

26

29

...

6

5

Rx

2

5

...

twisted
pair

8

1

Tx Flow

28

31

...

1

6

Rx Flow

3

6

...