Документ взят из кэша поисковой машины. Адрес
оригинального документа
: http://astra.prao.psn.ru/Molotov/Webpage/INFO/ph_cal.html
Дата изменения: Tue Apr 5 07:07:04 2005
Дата индексирования: Unknown
Кодировка:
Поисковые слова: ori
Phase calibration Fringe Fitting
Phase calibration Fringe Fitting
Left: A POSSM plot of the uncalibrated spectrum of DA 193 at 1.66 GHz on a baseline Bear Lakes to Noto.
The plot shows spectrum for a single IF to show the effects of the residual delay error more clearly.
The phase slope as a function of frequency is clear evidence for a small delay error in the correlator model.
Right: The same data as shown on the left, but corrected for a delay error and a residual fringe rate. Note how
the phase as a function of frequency is now flat. These data can now be averaged in frequency, if desired.
Left: A VPLOT plot of the uncalibrated amplitude (upper frame) and uncalibrated phase (lower frame) as a
function of time for the source DA 193 on a baseline HartRAO to Noto. Note how the phase varies as a
function of time. Unless the fringe rate is determined and removed, the data cannot be averaged in time.
Right: The same data as shown on the left, but corrected for the fringe rate. These data can now be averaged
in time, if desired.