Документ взят из кэша поисковой машины. Адрес
оригинального документа
: http://xmm.vilspa.esa.es/scisim/release/latest/help/changes/v2_0_4.html
Дата изменения: Thu Jan 13 19:12:52 2005 Дата индексирования: Sat Dec 22 15:35:03 2007 Кодировка: Поисковые слова: запрещенные спектральные линии |
SciSim v2.0.4 is a bug fix release of SciSim and contains only minor changes compared to v2.0.3. The input (configuration & data) files, as well as the ODF products are compatible with previous versions.
INSTRUME keyword may specify the instruments EMOS2 and RGS2, depending on the camera name specified in ESIM/RFCSIM (see SPR 372 and the ESIM/RFCSIM help documentation)
CCDNODE in the extension table 2 of the auxilary file of RGS is reporting the correct value
WINDOW?? keywords in the RGS ODF files take into account the read-out nodes.
Only the EPN camera in telescope1_config file relocated to (7500,2,-2).
SPR fixes implemented in this release:
372 : Cannot generate INSTRUME='EMOS2' files
377 : no negative cameraY PN output
378 : example background spectrum inconsistant
379 : ODF keyword "EXTNAME" not compliant with ODF ICD 2.0
380 : Incorrect implementation of WINDOW?? in RGS ODF production
381 : Incorrect value of CCDNODE in auxilary file of RGS ODF