Документ взят из кэша поисковой машины. Адрес оригинального документа : http://xmm.vilspa.esa.es/sas/6.5.0/doc/odfcheck/node15.html
Дата изменения: Tue Aug 16 07:09:27 2005
Дата индексирования: Sat Dec 22 11:03:40 2007
Кодировка:

Поисковые слова: запрещенные спектральные линии
Parameters XMM-Newton SAS Home Page
XMM-Newton Science Analysis System


odfcheck (odfcheck-0.18.2) [xmmsas_20050815_1803-6.5.0]

SAS compliance check Home Page Errors Home Index

Meta Index / Home Page

Parameters

This section documents the parameters recognized by this task (if any).

ParameterMand Type Default Constraints
skippreliminariesnoboolno 
If set odfcheck will assume that the user has already run cifbuild and odfingest, and that the relevant environment variables have been set. Otherwise cifbuild and odfingest will be run. The resulting CIF will have a name like RRRR_XXXXXXXXXX.cif, where RRRR_XXXXXXXXXX is the revolution/observation identifier for the current ODF.
 
checkattitudenoboolyes 
If set odfcheck will run the attitude diagnostics on the current ODF.
 
allowedbadattitudefractionnoreal65[0,100]
When running the attitude diagnostics odfcheck will issue a warning if the attitude is more than allowedbadattitudefraction% of the time more than nrms r.m.s. away from the median.
 
nrmsnoreal3$>0$
If the attitude diagnostic is being run, then the fraction of the time that the attitude differs more than nrms from the median pointing will be calculated.
 
allowedtimecorrelationfractionnoreal65[0,100]
When running the time correlation diagnostic odfcheck will issue a warning if more than allowedtimecorrelationfraction% of the available data points need to be discarded in order to reach a good fit.
 
checktimecorrelationnoboolyes 
If set odfcheck will run the time correlation diagnostics on the current ODF.
 
tcpintervalnoreal35$>0$
If the time correlation diagnostic is being run, time packets differing more than tcpinterval seconds from each other will be considered in estimating the statistical loss of telemetry.
 
checktelemetrynoboolyes 
If set odfcheck will run the telemetry loss diagnostics on the current ODF.
 
allowedtelemetrylossfractionnoreal5[0,100]
When running the telemetry loss diagnostic odfcheck will issue a warning if the estimated telemetry loss is larger than allowedtelemetrylossfraction%.
 
checkcountingmodenoboolyes 
If set odfcheck will run the EPIC counting mode diagnostics on the current ODF.
 
checkminimumpnenergynoboolyes 
If set odfcheck will run the PN minimum energy diagnostics on the current ODF.
 
checkompriorityfieldacquisitionnoboolyes 
If set odfcheck will run the OM priority field acquisition diagnostics on the current ODF.
 
checkhkgtinoboolyes 
If set odfcheck will run the housekeeping GTI diagnostics on the current ODF.
 
checkmostemperaturenoboolyes 
If set odfcheck will check if the EMOS cameras mean temperature during the science exposures was above the thresholds given with m1temperature and m2temperature.
 
m1temperaturenoreal33 
If the corresponfing diagnostics is activated odfcheck will use this value as the minimum mean temperature for the EMOS1 camera.
 
m2temperaturenoreal30 
If the corresponfing diagnostics is activated odfcheck will use this value as the minimum mean temperature for the EMOS2 camera.
 
checkpnenergynoboolyes 
If set odfcheck will check if the energy of every event in the PN science files is above a threshold. The latter is calculated from the housekeeping.
 
checksascompliancenoboolyes 
If set odfcheck will check that every FITS file in the ODF can be read with the SAS.
 
ParameterMand Type Default Constraints


SAS compliance check Home Page Errors Home Index

XMM-Newton SOC/SSC -- 2005-08-16