Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.eso.org/sci/data-processing/faq/why-do-i-get-the-message-that-no-slits-could-be-detected.html
Дата изменения: Unknown
Дата индексирования: Sun Apr 10 23:50:07 2016
Кодировка:

Поисковые слова: arp 220
ESO - Why do I get the message that "no slits could be detected", even though in the raw frames I can clearly see the slits?
 
 

Data Reduction Frequently Asked Questions

Why do I get the message that "no slits could be detected", even though in the raw frames I can clearly see the slits?

This problem occurs because the dispersion values included in the GRISM static calibration files refer to the current FORS2 CCDs. To reduce data obtained with the old CCD (which had 25 micron instead of 15 micron pixels), you will need to manually override the values for the dispersion [in ц…/pixel] from this table by specifying the --dispersion parameter in the fors_calib recipe. The value for the old CCD is 5/3 of the one in the GRISM_TABLE.