Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.energia.ru/eng/conversion/ecology/technology.html
Дата изменения: Unknown
Дата индексирования: Tue Oct 2 12:33:36 2012
Кодировка:

Поисковые слова: гелиакический заход
S.P.Korolev RSC Energia - ECOLOGICAL MONITORING
AUTOMATIC STATION OF ECOLOGICAL CONTROL
METROLOGICAL CHARACTERISTICS
BASIC PERFORMANCE SPECIFICATION
STATE OF ASEC DEVELOPMENT
 
 
homepage
AIR POLLUTION MONITORING
BASIC PERFORMANCE SPECIFICATION

Russian
   
Parameter ASEC ASAPC-M
Mass, kg 900 2700
Dimensions, mm Diameter 1900,
height 2830
3000У2400У2200
AC voltage, V 150-270 150-270
Mean daily power consumption, VA 1600 3000
Scheduled maintenance cycle, months 1 to 3 1 to 3
Warranted life-time of balloons and calibration mixed gases, months 12
(with subsequent replacement)
12
(with subsequent replacement)
Total mean service life, years 10 10
Possibility of remote programmable control of ASEC working modes from ecological center available available
Telemetry system supplying information from each station to ecological center on technical state of gas analyzing equipment and instruments, emergency situations and unauthorized opening of the station. available available
Operation under extreme climatic conditions: snowdrift, icing, stormy wind loads etc. available limited
Possibility of use as a mobile monitoring means available no
Possibility to display measured parameters and other parameters by circular creeping line on external surface of the station's body available no

The ASEC software and mathematical support provides the release of commands from the Ecolog automated work station, designed to remotely control the stations, in order to perform the following operations:

a) Switching on/off of power buses of measurement instruments;
b) Change of time of data transmission;
c) Change of data collection periodicity;
d) Switching on/off of interrogation of required measured parameters;
e) Calibration of measurement instruments on CO and CH with the use of calibration mixed gases*;
f) Station conservation and stopping.

* - Calibration mixed gasses are stored inside the balloons as part of ASEC. The mixed gas supply provides for one year of operation of the station, after that time it should be replenished. Gas analyzers on SO2 and NO/NO2/NOx are calibrated manually on a regular basis once a month/quarter (depending on technical state of instruments) with the use of special generator of mixed gases and sources of SO2 and NO2 microflows.

 

 

 

 

 

Official WEB-site of S.P.Korolev RSC Energia
E-mail:mail@rsce.ru