Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.atnf.csiro.au/research/pulsar/obssys/index.php?n=Observing.Setup
Дата изменения: Unknown
Дата индексирования: Wed Sep 15 00:00:24 2010
Кодировка:

Поисковые слова: внешние планеты
PmWiki | Observing / Setup
Recent Changes - Search:

edit SideBar

Setup

Multibeam Receiver Setup

The Parkes 21cm Multibeam Receiver consists of a 13-beam cooled 21cm receiver system, located at the prime focus of the 64m dish. The hexagonal feed cluster is designed by the CSIRO Division of Telecommunications and Industrial Physics.

Signals from 26 channels (note 2 polarizations) are down-converted and sent to the pulsar Multibeam filterbank system in the control room. This provides 2 x 96 x 3 MHz channels for each beam. Signals from the centre beam are tapped off and can be sent to other filterbank systems or the Caltech correlator. For pulsar observations, the 1st LO is normally set to 1582 MHz. There is a doubler in the focus cabin, so the reference frequency (normally set on the Rohde & Schwarz signal generator in Rack 5) is 791 MHz; the level is +11 dBm.

IF signals for the 13 beams and polarizations A and B come from the focus cabin to the Multibeam Cable Equalizer in Rack G. This corrects for the frequency-dependent cable loss and provides level setting in 1 db steps separately for each beam and polarization. It also splits off the signals for the Multibeam correlator. See Multibeam pulsar system for a block diagram of the system.

The Multibeam filterbank system accepts IFs in the range 1230 - 1518 MHz (total bandwidth 288 MHz for each polarization). Each beam and polarization is split into three subbands, each of which is downconverted to 64 - 160 MHz for input to the filterbank modules by the Multibeam up-down converter and band-splitter. This requires three LOs from the Multibeam LO module. Frequency Relations.

Input connections at the rear of the band-splitter are shown in Band splitters - back, and output plus LO connnections in the front are shown in Band splitters - front.

The 78 cables from the band-splitters go to the filterbanks in Racks E and F. Connections at the rear of each filterbank are shown in Filterbank Assignments. Ribbon cables take the filterbank outputs to the digitizer (see below). Sockets on the rear of the filterbanks are in parallel pairs, that is, sockets 1 and 2 of Crate A both have the polarization-summed outputs from the lowest subband (centred at 112 MHz) of beam 1. Each ribbon cable carries 32 signals to the digitizer.

Down-Converter Setup

We are gradually moving to integrate the Parkes Down-Converter into observing systems. Until the filter-bank systems are brought under TCS control, it is necessary to run scripts to set up the down-converter for different receiver/back-end configurations. These scripts live in /psr1/losetup/. Presently available scripts are:

1050fb.cmd:

For use with the 10/50cm receiver and PMCTRL configuration file 10-50.cfg. Sets up 192 x 3 MHz at 10cm, 256 x 0.25 MHz at 50cm. There are 64 unused f/b channels above the 192 x 3 MHz system. For just the 50cm system, use 50cm_64.cfg and for just the 10cm system use 10_576.cfg. (The latter records just the 192 channels containing data.)

hoh.cmd:

For use with the H-OH receiver and either of PMCTRL configuration files HOH_576.cfg (192 x 3 MHz) and HOH_256.cfg (512 x 0.5 MHz).

On any workstation:

%perseus lorun /psr1/losetup/name.cmd

Edit - History - Print - Recent Changes - Search
Page last modified on April 10, 2008, at 11:04 AM