Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.apo.nmsu.edu/arc35m/Instruments/ARCTIC/Development/ImagerPDR/GammaVac_Digitel_specsheet.pdf
Дата изменения: Thu Dec 5 20:44:00 2013
Дата индексирования: Thu Feb 27 21:13:31 2014
Кодировка:

Поисковые слова: внешние планеты
DIGITELTM ION PUMP CONTROLLERS


DIGITELTM ION PUMP CONTROLLERS

DIGITELTM ION PUMP CONTROLLERS
The DIGITEL family of Ion Pump controllers of fers the right balance of per formance, power and protection.

DIGITELTM SPCe | Small Pump Controller
The SPCe is a versatile way to fully operate ion pumps 0.2 ­ 75 l/s. An LCD pressure/current/voltage display along with standard serial communications makes the SPCe able to accommodate the needs of basic and advanced users. Nano amp resolution provides gauging capabilities using the appropriate ion pump set - up.

DIGITELTM LPCe | Large Pump Controller
Ion pumps 100 l/s and larger require higher currents for star ting and higher pressure operation. The LPCe supplies higher currents to a dedicated single ion pump (or up to four ion pumps in parallel) and has an easy- to - read touchscreen LCD display that simultaneously displays pressure, current, and voltage. Standard serial communications and eight set - points allow for easy system integration. The LPCe fi ts into any rack at just 3U high and 1/2 rack wide.

DIGITELTM MPCe | Multiple Pump Controller Ion Pump Control
Incorporating the same features as the LPCe, the MPCe allow for high current control of t wo ion pumps independently or up four in parallel. At 3U high and a full rack in width, the MPCe ideal for operating a wide variet y of ion pump confi gurations any system. s to is on

TSP/NEG Control
A TSP or NEG can be fully operated from the LCD touchscreen of the MPCe. They can be fi red manually or automatically based on the pressure of either ion pump the MPCe is monitoring. Timed modes also let the user have full control over exact parameters of operation. A single remote controller can operate up to eight TSP fi laments or t wo NEG pumps.


DIGITELTM ION PUMP CONTROLLERS

Ease of Use
Each DIGITELTM has a highly visible display. The SPCe has an easy- to read LCD that displays pressure, current and voltage. The LPCe and MPCe are each fully controlled with an intuitive touch panel LCD. Digital resolution down to 1nA is possible depending on pump size and c u r re n t re q u i re m e n t s .

Operator Safet y
The integrated SAFECONN high voltage interlock system eliminates electrical shocks and false positive pressure readings. The controller automatically shuts of f high voltage when the cable is disconnected from the ion pump or controller end. The system is isolated and guarantees ground, high voltage, and safet y connectivit y that prevents accidental arcing.

Communications
Serial communications (RS232, RS422, and RS485) are standard on all DIGITELTM products. Optional Ethernet protocol for advanced facilit y and instrumentation communications is available on all units.

Connectivit y
Each DIGITELTM has programmable analog and interlock capabilities. This allows for optimal fl exibilit y when integrating with standard or l e g a c y s e t p o i n t a n d a n a l o g m o n i t o r i n g s ys t e m s .

DIGITELTM Flexibility
The DIGITELTM line is fl exible enough to control a wide variet y of ion pump and TSP/NEG confi gurations. The LPCe and MPCe can operate up to four ion pumps simultaneously or independent Example Configuration 1 Four diode ion pumps in and Single TSP operation. operation of one or t wo ion pumps, respectively. The MPCe is capable of controlling one or t wo TSP/NEG car tridges independently. Example Configuration 2 Three diode ion pumps, in parallel, one triode ion pump and Dual TSP/NEG operation.

Configuration Part String for Example 2


DIGITELTM ION PUMP CONTROLLERS

DIGITEL ION PUMP CONTROLLERS
SPECIFICATIONS
INPUT POWER Voltage Frequency OUTPUT POWER Independent Outputs Open Circuit Voltage Current (maximum) Watts (maximum) Resolution HIGH VOLTAGE CONNEC TIONS DISPL AY Type Readouts ANALOG OUTPUTS Voltage Current/Pressure SE TPOINTS COMMUNIC ATIONS linear, configurable linear or logarithmic, configurable One relay, one TTL Local/Remote/Full Ethernet Serial: 232, 422, 485 CONFOR MIT Y TO NOR MS EN 55011 Class A, IEC 801-2 EN 801-3, IEC 801-4, EN 61010-1 WE IGHT, KG (LBS) 1.5 (3.3) linear, configurable linear or logarithmic, configurable Four relay, four TTL Local/Remote/Full Ethernet Serial: 232, 422, 485 EN 55011 Class A, IEC 801-2 EN 801-3, IEC 801-4, EN 61010-1 16.8 (37) linear, configurable linear or logarithmic, configurable Four relay, four TTL Local/Remote/Full Ethernet Serial: 232, 422, 485 EN 55011 Class A, IEC 801-2 EN 801-3, IEC 801-4, EN 61010-1 16.8 (37) minimum 25.4 (56) maximum SIZE 2U high, 1/4 rack wide 313 mm (12.3 in.) deep ADDITIONAL FE ATURES SAFECONN AUTOSTART/AUTORUN High Voltage Enable Fowler-Nordheim Calibration High-Pot Capability COMPATIBILIT Y (l/s) Mini/3S 10-75 100-300 400-1200 X X X X X X X 3U high, 1/2 rack wide 438 mm (17.2 in.) deep SAFECONN AUTOSTART/AUTORUN High Voltage Enable 3U high, full rack wide 438 mm (17.2 in.) deep SAFECONN AUTOSTART/AUTORUN High Voltage Enable Remote TSP Control LCD Pressure, current, voltage, and programmable options 1/4 VGA touchscreen LCD Pressure, current, voltage, and programmable options 1/4 VGA touchscreen LCD Pressure, current, voltage, and programmable options 1 3000-7000 vdc (+/- configurable) 50 mA 50 1 nA One 10kV SHV or Fischer 1 +/-5600 or 7000 vdc 100 mA 200 1 nA 1-4, 10kV SHV or Fischer 1 or 2 +/-5600 or 7000 vdc 100 mA or 500 mA 1000 1 nA / 0.1 uA 1-4, 10kV SHV or Fischer 90-240 vac or 24 vdc 48-62 Hz 90-130 or 200-240 volts 48 - 62 Hz 90-130 or 200-240 volts 48 - 62 Hz

SPCe

LPCe

MPCe

GAMMA VACUUM
2915 133rd Street West Shakopee, MN 55379 | USA 80 0.237.3603 T | 952.445.4841 P 952.445.7615 F gammavacuum.com | info@gammavacuum.com